Comparing the Full-Threshold and Swedish Interactive Thresholding Algorithms for Short-Wavelength Automated Perimetry
Open Access
- 1 April 2009
- journal article
- research article
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Opthalmology & Visual Science
- Vol. 50 (4) , 1726-1733
- https://doi.org/10.1167/iovs.08-2718
Abstract
Purpose. To compare the Swedish interactive thresholding algorithm (SITA) with the full-threshold (FT) strategy for short-wavelength automated perimetry (SWAP). methods. One eye of 286 patients with glaucomatous optic neuropathy (GON) and 289 age-matched participants without GON from the Diagnostic Innovations in Glaucoma Study (DIGS) and the African Descent and Glaucoma Evaluation Study (ADAGES) were classified with optic disc stereophotographs taken within 6 months of visual field testing, conducted within a 3-month period. Six parameters were derived per test, including pattern standard deviation (PSD) and the number of pattern deviation plot (PDP) points triggered at P < 0.05). Sensitivity and specificity using the STATPAC PSD at 95% (P < 5%) and 99.5% (P < 0.05%) was similar between algorithms. Severity correlated significantly between algorithms (P < 0.001), although there was bias for SWAP-SITA to suggest more severe loss. SWAP-SITA required significantly less test time than did SWAP-FT (P < 0.001). Mean differences in PSD, PDP <1%, and MD between algorithms were not clinically significant. conclusions. Both algorithms performed similarly when equated for specificity. The reduced test duration makes SWAP-SITA the better choice. Testing with both algorithms within a short period is recommended for confirmation of results when switching from FT to SITA.Keywords
This publication has 23 references indexed in Scilit:
- Visual Function-Specific Perimetry to Identify Glaucomatous Visual Loss Using Three Different Definitions of Visual Field AbnormalityInvestigative Opthalmology & Visual Science, 2009
- Identifying Glaucomatous Vision Loss with Visual-Function–Specific Perimetry in the Diagnostic Innovations in Glaucoma StudyInvestigative Opthalmology & Visual Science, 2006
- Diagnostic Sensitivity of Fast Blue–Yellow and Standard Automated Perimetry in Early GlaucomaOphthalmology, 2006
- Use of Progressive Glaucomatous Optic Disk Change as the Reference Standard for Evaluation of Diagnostic Tests in GlaucomaAmerican Journal of Ophthalmology, 2005
- Relationship of optic disk topography and visual function in patients withlarge cup-to-disk ratiosAmerican Journal of Ophthalmology, 2003
- Short-wavelength automated perimetryOphthalmology Clinics of North America, 2003
- Structure and function evaluation (SAFE): II. comparison of optic disk and visual field characteristicsAmerican Journal of Ophthalmology, 2003
- Diagnostic value of short-wavelength automated perimetryCurrent Opinion in Opthalmology, 1996
- The 'blue-on' opponent pathway in primate retina originates from a distinct bistratified ganglion cell typeNature, 1994
- Blue-on-Yellow Perimetry Can Predict the Development of Glaucomatous Visual Field LossArchives of Ophthalmology (1950), 1993