Evaluation of Fibrin Glue in Rat Sciatic Nerve Repairs
- 1 September 1986
- journal article
- research article
- Published by Wolters Kluwer Health in Plastic and Reconstructive Surgery
- Vol. 78 (3) , 369-373
- https://doi.org/10.1097/00006534-198609000-00015
Abstract
Using the rat sciatic nerve model, we evaluated the merits of homologous fibrin glue in the repair of peripheral nerve transections as compared to standard epineural suture repairs. A total of four study groups were used, with 10 animals assigned to each group. In group I, the transected sciatic nerve was repaired with six interrupted 10–0 nylon sutures; in group II, only two interrupted sutures were used; in group III, a two-suture repair was reinforced with fibrin glue; and in group IV, only fibrin glue was used. All animals were sacrificed at 8 weeks, and histologie sections evaluated. When fibrin alone was used, dehiscence occurred in 80 percent of the animals, and as reinforcement of a two-suture repair, it only increased the inflammatory reaction.Keywords
This publication has 0 references indexed in Scilit: