Aortic Valve/Root Interactions in Porcine Hearts: Implications for Bioprosthetic Valve Sizing
- 1 December 1991
- journal article
- Published by Hindawi Limited in Journal of Cardiac Surgery
- Vol. 6 (4) , 482-489
- https://doi.org/10.1111/j.1540-8191.1991.tb00349.x
Abstract
The implantation of aortic allografts as well as stentless, freehand porcine xenograft valves requires proper sizing of the graft for the recipient aortic root. To visualize the aortic valve in motion and measure the cyclic expansion of the aortic root, we developed an isolated porcine heart model and a computerized three-dimensional reconstruction technique. Dynamic and static expansions of the aortic root were obtained from beating and arrested porcine hearts, and additional static expansions at varying pressures were measured from reconstructed three-dimensional models of valves obtained with high-resolution magnetic resonance imaging. Measurements of aortic root expansion have shown that it is highly dependent upon the pressures imposed on the heart. Although the aortic root expanded by only 5% between systolic pressures of 60 and 100 mmHg, the total expansion was up to 40% between rest and cyclic pressurizing to 100 mmHg. This data suggest that unstented xenograft valves should be sized 30% to 40% larger than the collapsed size of the recipient aorta. Proper sizing of valves on stents should also be attempted to reduce the large amount of leaflet redundancy that current stenting techniques produce.Keywords
This publication has 8 references indexed in Scilit:
- Automated 3-D reconstruction of vascular structures from high definition castsIEEE Transactions on Biomedical Engineering, 1991
- A computerized system for video analysis of the aortic valveIEEE Transactions on Biomedical Engineering, 1990
- Mechanical testing of cryopreserved aortic allograftsThe Journal of Thoracic and Cardiovascular Surgery, 1990
- Analysis of the bending behaviour of porcine xenograft leaflets and of natural aortic valve material: Bending stiffness, neutral axis and shear measurementsJournal of Biomechanics, 1989
- Tissue Buckling as a Mechanism of Bioprosthetic Valve FailureThe Annals of Thoracic Surgery, 1988
- The Use of Free-hand Unstented Aortic Valve Allografts for Replacement of the Aortic ValveJournal of Cardiac Surgery, 1986
- Stress analysis of porcine bioprosthetic heart valves in vivoJournal of Biomedical Materials Research, 1982
- The dynamic aortic rootThe Journal of Thoracic and Cardiovascular Surgery, 1976