Protein identification in cerebrospinal fluid using packed capillary liquid chromatography Fourier transform ion cyclotron resonance mass spectrometry
- 24 February 2003
- journal article
- research article
- Published by Wiley in Proteomics
- Vol. 3 (2) , 184-190
- https://doi.org/10.1002/pmic.200390027
Abstract
The identification and characterization of proteins in complex biological samples such as body fluids, require powerful and reliable tools. Mass spectrometry is today one of the most important methods in such research. This paper reports on the results from the first experiment where a tryptic digest of cerebrospinal fluid was analyzed applying reversed phase liquid chromatography coupled on-line to a 9.4 T Fourier transform ion cyclotron resonance mass spectrometer. In total, 70 204 peaks were detected, which originated from 16 296 isotopic clusters corresponding to 6551 unique peptide masses. From these masses, 39 proteins were identified in the sample. The amount of sample required for one experiment corresponds to 32 μL of cerebrospinal fluid.Keywords
This publication has 27 references indexed in Scilit:
- Analysis of the human lumbar cerebrospinal fluid proteomeElectrophoresis, 2002
- Liquid chromatography and electron‐capture dissociation in Fourier transform ion cyclotron resonance mass spectrometryRapid Communications in Mass Spectrometry, 2002
- Micro‐high‐performance liquid chromatography/Fourier transform mass spectrometry with electron‐capture dissociation for the analysis of protein enzymatic digestsRapid Communications in Mass Spectrometry, 2002
- Mass measurement errors caused by “local” frequency perturbations in FTICR mass spectrometryJournal of the American Society for Mass Spectrometry, 2002
- Peptide mapping of proteins in human body fluids using electrospray ionization Fourier transform ion cyclotron resonance mass spectrometryMass Spectrometry Reviews, 2002
- Prediction of peptide retention times in reversed-phase high-performance liquid chromatography I. Determination of retention coefficients of amino acid residues of model synthetic peptidesPublished by Elsevier ,2001
- A simple and robust conductive graphite coating for sheathless electrospray emitters used in capillary electrophoresis/mass spectrometryRapid Communications in Mass Spectrometry, 2001
- A 9.4 T Fourier Transform Ion Cyclotron Resonance Mass Spectrometer: Description and PerformanceEuropean Journal of Mass Spectrometry, 2000
- Application of micro-electrospray liquid chromatography techniques to FT-ICR MS to enable high-sensitivity biological analysisJournal of the American Society for Mass Spectrometry, 1998
- External accumulation of ions for enhanced electrospray ionization fourier transform ion cyclotron resonance mass spectrometryJournal of the American Society for Mass Spectrometry, 1997