Results of silicon strip detector readout using a CMOS low power microplex (MX1)
- 1 February 1988
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 35 (1) , 176-180
- https://doi.org/10.1109/23.12700
Abstract
A system for reading out silicon strip detectors has been fabricated on a CMOS integrated circuit. The chip consists of an array of 128 amplifiers with a single multiplexed output. These chips have been bonded to a 256-channel silicon strip detector. Results are reported on the electrical parameters of the chips and on data taken during exposure of the instrumented detectors to minimum-ionizing beta particles. The radiation tolerance of the device has been investigated. The MX1 is working to specification and is presently being incorporated into equipment.Keywords
This publication has 2 references indexed in Scilit:
- Development of high density readout for silicon strip detectorsNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1984
- Energy loss and energy straggling of protons and pions in the momentum range 0.7 to 115 GeV/cPhysical Review A, 1983