"Optimally Spaced" Excimer Laser Coronary Catheters: Performance Analysis
- 1 February 2001
- journal article
- research article
- Published by Mary Ann Liebert Inc in Journal of Clinical Laser Medicine & Surgery
- Vol. 19 (1) , 9-14
- https://doi.org/10.1089/104454701750066884
Abstract
Background: Excimer laser angioplasty is a percutaneous treatment modality for management of selected patients with severe obstructive coronary artery disease. This technology entails application of multifiber catheters that vaporize intra-arterial plaque and thrombus with the 308-nm wavelength light. A coronary laser catheter ("OS") with increased space between its optic fibers (90 μ) at the tip was recently developed. The previous design used a closely packed fiber bundle ("CP") with a smaller space between the fibers (77 μ). We sought to determine the ablation characteristics of the new, OS design. Methods: Experiments testing the new catheter and comparing it to the existing catheter included: (1) measurement of the laser output beam sizes and divergences; (2) evaluation of particulate matter generation during ablation of atherosclerotic tissue; (3) measurement of ablation hole sizes and tissue penetration rates; (4) histopathologic examination of laser-induced in vivo vessel wall injury. Results: The new OS catheters produce a wider beam with higher divergence than the traditional CP catheters (6.7° vs. 4.7°, respectively). Testing two different levels of energy revealed the generation of a reduced number of particulate matter and shallower penetration depth with the OS catheter compared with traditional CP catheters. The OS catheters created a larger diameter of ablated hole than the CP catheters (for 2.0-mm catheters: 2.7 mm2 vs. 1.5 mm2, respectively, p = 0.01]. Lasing with the OS catheters with slow advancement rates (0.2-0.5 mm/sec) resulted in creation of significantly larger-diameter holes than those produced at higher speeds (1-3 mm/sec). The in vivo vessel wall injury scores were similar among the two types of catheters tested. Conclusions: A new design of spaced optical fibers for coronary laser catheters provides increased tissue ablation in comparison to the traditional closely packed fibers catheter. Slow advancement rates during lasing with the new OS catheter are crucial for achievement of adequate plaque debulking.Keywords
This publication has 10 references indexed in Scilit:
- Stenting After Optimal Lesion Debulking (SOLD) RegistryCirculation, 1998
- Plaque Excision Combined With Stent PlacementCirculation, 1998
- Plaque Removal and Thrombus Dissolution with the Photoacoustic Energy of Pulsed-Wave Lasers – Biotissue Interactions and Their Clinical ManifestationsCardiology, 1996
- Mechanisms of Lumen Enlargement After Excimer Laser Coronary AngioplastyCirculation, 1995
- Percutaneous excimer laser coronary angioplasty: Results in the first consecutive 3,000 patientsJournal of the American College of Cardiology, 1994
- A New, Safer Lasing Technique for Laser‐Facilitated Coronary AngioplastyJournal of Interventional Cardiology, 1993
- Intraluminal vapor bubble induced by excimer laser pulse causes microsecond arterial dilation and invagination leading to extensive wall damage in the rabbit.Circulation, 1993
- Clinical success, complications and restenosis rates with excimer laser coronary angioplastyThe American Journal of Cardiology, 1992
- Origin of arterial wall dissections induced by pulsed excimer and mid-infrared laser ablation in the pigJournal of the American College of Cardiology, 1992
- PATHOLOGIC ANALYSIS OF PHOTOTHERMAL AND PHOTOMECHANICAL EFFECTS OF LASER–TISSUE INTERACTIONSPhotochemistry and Photobiology, 1991