Virtual cystoscopy based on helical CT scan datasets: perspectives and limitations.
- 1 March 1998
- journal article
- research article
- Published by Oxford University Press (OUP) in The British Journal of Radiology
- Vol. 71 (843) , 262-267
- https://doi.org/10.1259/bjr.71.843.9616234
Abstract
The purpose of the study was to simulate cystoscopy based on three-dimensional helical CT scan datasets in real-time in patients with tumours of the urinary bladder. A helical CT scan with double detector technology was carried out pre-operatively in 11 patients with histologically confirmed carcinoma of the urinary bladder and one patient with chronic cystitis. A non-enhanced scan was first performed, followed by an examination in the early phase of contrast medium enhancement. Further images were acquired after adequate filling of the bladder with contrast medium, approximately 30 min after injection. These data were transferred to a separate graphic computer workstation and reconstructed. The results were then compared with the cystoscopic and histopathological findings. All tumours of the urinary bladder identified at fibreoptic cystoscopy were shown on virtual cystoscopy. The best reconstruction results were obtained from data acquired 30 min after injection of contrast medium. The ureteric orifices were not visualized at virtual cystoscopy. These data lead us to conclude that, at present, virtual cystoscopy has not reached the quality of fibreoptic examination and remains restricted to use in specific cases, for example patients with urethral strictures.Keywords
This publication has 11 references indexed in Scilit:
- Dreidimensionale Oberflächendarstellung des Larynx und der Trachea mittels Spiral-CT: Virtuelle EndoskopieRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 1996
- Variability of consecutive in vivo MR flow measurements in the main portal vein.American Journal of Roentgenology, 1996
- Perspective volume rendering of CT and MR images: applications for endoscopic imaging.Radiology, 1996
- What are the indications for use of water-soluble contrast agent enemas in colon distension?American Journal of Roentgenology, 1996
- Human aorta: preliminary results with virtual endoscopy based on three-dimensional MR imaging data sets.Radiology, 1996
- Bladder cancer, 1996CA: A Cancer Journal for Clinicians, 1996
- Virtual BronchoscopyChest, 1996
- CT cystoscopy: an innovation in bladder imaging.American Journal of Roentgenology, 1996
- Cancer statistics, 1996CA: A Cancer Journal for Clinicians, 1996
- Marching cubes: A high resolution 3D surface construction algorithmACM SIGGRAPH Computer Graphics, 1987