Method for decreasing the statistical variance of stereological estimates
- 1 September 1983
- journal article
- research article
- Published by Wiley in The Anatomical Record
- Vol. 207 (1) , 89-106
- https://doi.org/10.1002/ar.1092070110
Abstract
Three methods are described for decreasing the statistical variance of stereological estimates. Methods 1 uses profile boundaries and surface densities of nuclear membranes, measured in thin sections, to estimate the mean diameter, surface area, and numerical density of spherical and nonspherical nuclei. For the guinea pig pancreas (number(m) = 4), the standard deviations (s.d.) as a percent of the mean for the estimates of the diameters of the exocrine, duct, and endothelial cell nuclei were 1.5%, 3.3% and 1.4%. The estimate for the mean diameter of exocrine nuclei (6.4 ± 0.1 μm) was based on a spherical model, whereas the estimates for the diameters of the nonspherical (and nonconvex) nuclei of the duct (6.4 ± 0.2 μm) and endothelial (6.7 ± 0.1 μm) cells were calculated from the numerical density of the exocrine cells and the relative frequenceis of the three cell types (determined from serial reconstructions). In an average cubic centimeter, there were 6.17 × 108 ± 0.32 × 108 (s.d. 5.1% of mean) exocrine cells, 1.64 × 108 ± 0.18 × 108 (10.9%) duct cells, and 0.803 × 108 ± 0.13 × 108 (16.6%) endothelial cells. In contrast to method 1, conventional stereological approaches were found to have standard deviations two‐to eightfold larger. Method 2 uses a mean nuclear surface area and a ratio of surface densities to estimate the surface area of a membrane compartment in an average cell. A s.d. equal to 6.5% of the mean was found for the surface are of the outer mitochondrial membrane in an average exocrine cell (672 ± 43.6 μm2), which represented an almost fourfold reduction in the s.d. compared with an earlier estimate (Bolender, 1974). Method 3 relates the surface area of a membrane compartment to a standard number of cells. Referenced to 106 cells, for example, the surface area of the inner nuclear membrane of endothelial cells had a s.d. equal to 2.9% of the mean, whereas the surface density of the same membrane compartment—referenced to a cm3 to cells—had a s.d. at 19.1% of the mean. In this case, method 3 produced almost a sevenfold reduction in the standard deviation. Similar results were found for exocrine and duct cells.The results of the study indicate that the standard deviation of a stereological estimate can be reduced to a miniumum by using a mean nuclear profile boundary to generate an estimate for a nuclear numerical density, which, in turn, can be combined with a surface density to obtain average cell information.This publication has 19 references indexed in Scilit:
- PCS-I — A point counting stereology program for cell biologyComputer Programs in Biomedicine, 1982
- STEREOLOGY AND ITS USES IN CELL BIOLOGY*Annals of the New York Academy of Sciences, 1982
- On the relative efficiencies of alternative ratio estimators for morphometric analysis of cell membrane surface featuresJournal of Microscopy, 1981
- Stereology: Applications to PharmacologyAnnual Review of Pharmacology and Toxicology, 1981
- Surface area ratios. I. A stereological method for estimating average cell changes in membrane surface areasThe Anatomical Record, 1979
- Estimation of the mean caliper diameter of cell nucleiJournal of Microscopy, 1978
- Stereological analysis of hepatic fine structure in the Fischer 344 rat. Influence of sublobular location and animal age.The Journal of cell biology, 1978
- STEREOLOGICAL ANALYSIS OF THE GUINEA PIG PANCREASThe Journal of cell biology, 1974
- Bestimmung der Größenverteilung von Kugeln aus SchnittkreisradienBiometrische Zeitschrift, 1970