Differentiation between gaseous and formed embolic materials in vivo. Application in prosthetic heart valve patients.
- 1 August 1994
- journal article
- research article
- Published by Wolters Kluwer Health in Stroke
- Vol. 25 (8) , 1559-1563
- https://doi.org/10.1161/01.str.25.8.1559
Abstract
Doppler emboli detection is an established technique, but the nature of the underlying embolic material remains unclear. The intensity and spectral distribution of emboli signals could help to distinguish between signals arising from formed and gaseous emboli. We undertook this study to develop and evaluate a differentiation algorithm based on the spectral characteristics of emboli signals. Subsequently the algorithm was applied to patients with mechanical prosthetic cardiac valves. Emboli signals detected in patients with carotid disease, acute stroke, and atrial fibrillation were used as formed emboli data, and signals detected in patients undergoing cardiac catheterization studies were used as gaseous emboli data. For each embolus signal, the maximal amplitude, the sum of amplitudes, and the spectral intensity distribution were calculated. Two hundred emboli signals from each category were used to develop a differentiation algorithm, which was subsequently evaluated on 501 additional solid and 995 gaseous emboli signals. The same algorithm was used to analyze 5958 emboli signals detected in 60 patients with mechanical prosthetic valves. The best results were obtained with an algorithm based on both the maximal amplitude and the sum of amplitudes (sensitivity, 99%; specificity, 96.5%). On subsequent evaluation, the sensitivity and specificity of the algorithm were 99.6% and 89.8%, respectively. Of the 5958 emboli signals detected in prosthetic valve patients, 92.4% were classified as gaseous. Differentiation between gaseous and formed emboli signals, as detected by transcranial Doppler in vivo, is feasible by means of spectral analysis. Application of the differentiation algorithm in prosthetic valve patients suggests that the embolic material in these patients is gaseous. The possibility of distinguishing between different formed embolic materials with this technique remains to be evaluated.Keywords
This publication has 17 references indexed in Scilit:
- Quantification of ultrasound emboli signals in patients with cardiac and carotid disease.Stroke, 1993
- Detection of intracranial emboli in patients with symptomatic extracranial carotid artery disease.Stroke, 1992
- Mobile strands are frequently attached to the St. Jude Medical mitral valve prosthesis as assessed by two-dimensional transesophageal echocardiographyAmerican Heart Journal, 1992
- Detection of arterial emboli using Doppler ultrasound in rabbits.Stroke, 1991
- Microemboli and Cerebral Impairment During Cardiac SurgeryVascular Surgery, 1990
- The Transcranial Doppler Can Image Microaggregates of Intracranial Air and Particulate MatterJournal of Neurosurgical Anesthesiology, 1989
- The use of Doppler ultrasound in the assessment of microemboli during cardiac surgeryPerfusion, 1989
- The Detection of Microemboli in the Middle Cerebral Artery during Cardiopulmonary Bypass: A Transcranial Doppler Ultrasound Investigation Using Membrane and Bubble OxygenatorsThe Annals of Thoracic Surgery, 1987
- Assessment of Diagnostic TechnologiesScience, 1979
- The Relative Operating Characteristic in PsychologyScience, 1973