Performance comparison between the high‐speed Yokogawa spinning disc confocal system and single‐point scanning confocal systems
- 27 April 2005
- journal article
- research article
- Published by Wiley in Journal of Microscopy
- Vol. 218 (2) , 148-159
- https://doi.org/10.1111/j.1365-2818.2005.01473.x
Abstract
Fluorescence microscopy of the dynamics of living cells presents a special challenge to a microscope imaging system, simultaneously requiring both high spatial resolution and high temporal resolution, but with illumination levels low enough to prevent fluorophore damage and cytotoxicity. We have compared the high-speed Yokogawa CSU10 spinning disc confocal system with several conventional single-point scanning confocal (SPSC) microscopes, using the relationship between image signal-to-noise ratio and fluorophore photobleaching as an index of system efficiency. These studies demonstrate that the efficiency of the CSU10 consistently exceeds that of the SPSC systems. The high efficiency of the CSU10 means that quality images can be collected with much lower levels of illumination; the CSU10 was capable of achieving the maximum signal-to-noise of an SPSC system at illumination levels that incur only at 1/15th of the rate of the photobleaching of the SPSC system. Although some of the relative efficiency of the CSU10 system may be attributed to the use of a CCD rather than a photomultiplier detector system, our analyses indicate that high-speed imaging with the SPSC system is limited by fluorescence saturation at the high levels of illumination frequently needed to collect images at high frame rates. The high speed, high efficiency and freedom from fluorescence saturation combine to make the CSU10 effective for extended imaging of living cells at rates capable of capturing the three-dimensional motion of endosomes moving up to several micrometres per second.Keywords
This publication has 23 references indexed in Scilit:
- Determining the position of the cell division planeNature, 2003
- Spindle orientation in Saccharomyces cerevisiae depends on the transport of microtubule ends along polarized actin cablesThe Journal of cell biology, 2003
- Three-dimensional analysis of post-Golgi carrier exocytosis in epithelial cellsNature Cell Biology, 2003
- Actin dynamics in the contractile ring during cytokinesis in fission yeastNature, 2002
- Real-time observation of hemodynamic changes in glomerular aneurysms induced by anti–Thy-1 antibodyKidney International, 2001
- Formation of Planar and Spiral Ca2+ Waves in Isolated Cardiac MyocytesBiophysical Journal, 1999
- A quantitative comparison of image restoration methods for confocal microscopyJournal of Microscopy, 1997
- Video-Rate Confocal MicroscopyPublished by Springer Nature ,1995
- Direct View Confocal Imaging Systems Using a Slit AperturePublished by Springer Nature ,1995
- Signal-to-Noise in Confocal MicroscopesPublished by Springer Nature ,1995