Detection of Colonic Polyps in a Phantom Model: Implications for Virtual Colonoscopy Data Acquisition
- 1 July 1998
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 22 (4) , 656-663
- https://doi.org/10.1097/00004728-199807000-00028
Abstract
Virtual colonoscopy is a new method of colon examination in which computer-aided 3D visualization of spiral CT simulates fiberoptic colonoscopy. We used a colon phantom containing various-sized spheres to determine the influence of CT acquisition parameters on lesion detectability and sizing. Spherical plastic beads with diameter of 2.5, 4, 6, 8, and 10 mm were randomly attached to the inner wall of segments of plastic tubing. Groups of three sealed tubes were scanned at 3/1, 3/2, 5/1, and 5/2 collimation(mm)/pitch settings in orientations perpendicular and parallel to the scanner gantry. For each acquisition, image sets were reconstructed at intervals from 0.5, to 5.0 mm. Two blinded reviewers assessed transverse cross-sections of the phantoms for bead detection, using source CT images for images for acquisitions obtained with the tubes oriented perpendicular to the gantry and using orthogonal reformatted images for scans oriented parallel to the gantry. Detection of beads of ≥4 mm was 100% for both tube orientations and for all collimator/pitch settings and reconstruction intervals. For the 2.5 mm beads, detection decreased to 78-94% for 5 mm collimation/pitch 2 scans when the phantom sections were oriented parallel to the gantry (p = 0.01). Apparent elongation of beads in the slice direction occurred as the collimation and pitch increased. The majority of the elongation (∼75%) was attributed to changing the collimator from 3 to 5 mm, with the remainder of the elongation due to doubling the pitch from 1 to 2. CT scanning at 5 mm collimation and up to pitch 2 is adequate for detection of high contrast lesions as small as 4 mm in this model. However, lesion size and geometry are less accurately depicted than at narrower collimation and lower pitch settings.Keywords
This publication has 19 references indexed in Scilit:
- Detection of colorectal polyps with CT colography: initial assessment of sensitivity and specificity.Radiology, 1997
- Virtual colonoscopy: what will the issues be?American Journal of Roentgenology, 1997
- Small simulated polyps in pig colon: sensitivity of CT virtual colography.Radiology, 1997
- Colorectal polyp detection with CT colography: two- versus three-dimensional techniques. Work in progress.Radiology, 1996
- Perspective volume rendering of CT and MR images: applications for endoscopic imaging.Radiology, 1996
- Detection of colorectal polyps by computed tomographic colography: Feasibility of a novel techniqueGastroenterology, 1996
- Technical optimization of spiral CT for depiction of renal artery stenosis: in vitro analysis.Radiology, 1995
- Longitudinal resolution in volumetric x-ray computerized tomography-Analytical comparison between conventional and helical computerized tomographyMedical Physics, 1994
- A Comparison of Conventional and Spiral CTJournal of Computer Assisted Tomography, 1994
- Prevention of Colorectal Cancer by Colonoscopic PolypectomyNew England Journal of Medicine, 1993