Comparison of Western blot (immunoblot) based on recombinant-derived p41 with conventional tests for serodiagnosis of human immunodeficiency virus infections
- 1 January 1988
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 26 (1) , 116-120
- https://doi.org/10.1128/jcm.26.1.116-120.1988
Abstract
To evaluate the performance of a serological test for human immunodeficiency virus type 1 (HIV-1) infections based on the use of a recombinant envelope gene-derived protein as the antigen, we caused expression of a 1.4-kilobase fragment of HIV DNA that codes for the complete gp41 transmembrane protein in an Escherichia coli expression vector and used Western blots (WB; immunoblots) prepared with recombinant material (pEX-41) to detect antibodies to HIV-1. This test detected all 339 sera which were positive by a combination of conventional serodiagnostic assays and produced no false-positive results with 311 negative samples. Also no false-positive results were obtained with 20 sera from systemic lupus erythematosus patients which had high titers of cross-reactive autoantibodies. In six cases, the pEX-41 WB proved to be more sensitive than individual assays applied on their own, and in five cases it was even more sensitive than a combination of conventional assays. We tested 221 sera in both our pEX-41 WB and a commercially available recombinant enzyme immunoassay (EIA [Abbott]). The results were indentical in 188 cases. A total of 27 sera containing antibodies to gp41 as demonstrated in the pEX-41 WB, as well as the Abbott recombinant EIA, had no antibodies to the recombinant core antigen as measured in the Abbott EIA. However, 25 of these sera did stain the 24-kilodalton band on a WB with purified virus. Six sera that were positive in all of the conventional confirmatory assays and reacted strongly with the pEX-41 WB did not recognize the surface antigen used in the Abbott recombinant EIA. We conclude that the use of WB prepared with recombinant-derived p41 offers a very sensitive and specific method to detect antibodies to HIV.This publication has 25 references indexed in Scilit:
- RAPID, EASY, AND ECONOMICAL SCREENING TEST FOR ANTIBODIES TO HUMAN IMMUNODEFICIENCY VIRUSThe Lancet, 1987
- HIV-2 INFECTION IN TWO HOMOSEXUAL MEN IN FRANCEThe Lancet, 1987
- FINDINGS IN FOUR HTLV-IV SEROPOSITIVE WOMEN FROM WEST AFRICAThe Lancet, 1986
- FALSE-POSITIVE IMMUNOBLOT RESULTS WITH ANTIBODIES AGAINST HUMAN IMMUNODEFICIENCY VIRUSThe Lancet, 1986
- WHICH ANTI-HTLV III/LAV ASSAYS FOR SCREENING AND CONFIRMATORY TESTING?The Lancet, 1985
- HTLV-III env gene products synthesized in E. coli are recognized by antibodies present in the sera of AIDS patientsCell, 1985
- An HTLV-III peptide produced by recombinant DNA is immunoreactive with sera from patients with AIDSNature, 1985
- Expression in Escherichia coli of Open Reading Frame Gene Segments of HTLV-IIIScience, 1985
- Complete nucleotide sequence of the AIDS virus, HTLV-IIINature, 1985
- Electrophoretic transfer of proteins from polyacrylamide gels to nitrocellulose sheets: procedure and some applications.Proceedings of the National Academy of Sciences, 1979