Time‐resolved flow measurement in the isolated rat heart: Characterization of left coronary artery stenosis
Open Access
- 20 August 2003
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 50 (3) , 449-452
- https://doi.org/10.1002/mrm.10563
Abstract
The investigation of flow behavior in coronary arteries is of great importance for an understanding of heart failure and heart regulation mechanisms. The purpose of the present study was to demonstrate that flow velocity can be quantified in the coronary arteries of the isolated rat heart with high‐resolution phase contrast MRI. A phase contrast cine‐FLASH imaging sequence was used for flow quantification with an in‐plane resolution of 70 μm and a slice thickness of 500 μm. With time‐resolved measurements, coronary flow over the heart cycle was analyzed. Furthermore, the flow behavior in coronary stenosis was investigated and the degree of stenosis was quantified with MR phase contrast imaging. To achieve the required spatial resolution and a satisfactory signal‐to‐noise ratio, the experiments were performed at 11.75 T. Magn Reson Med 50:449–452, 2003.Keywords
Funding Information
- SFB 355
- Graduiertenkolleg “Magnetische Kernresonanz in vivo und in vitro,” Deutsche Forschungsgemeinschaft
This publication has 21 references indexed in Scilit:
- Magnetic Resonance Imaging of Coronary Arteries and Heart Valves in a Living Mouse: Techniques and Preliminary ResultsJournal of Magnetic Resonance, 2000
- Correction of partial‐volume effects in phase‐contrast flow measurementsJournal of Magnetic Resonance Imaging, 1995
- Quantitative NMR imaging of flowConcepts in Magnetic Resonance, 1993
- Analysis of systematic and random error in MR volumetric flow measurementsMagnetic Resonance in Medicine, 1993
- Accuracy of phase‐contrast flow measurements in the presence of partial‐volume effectsJournal of Magnetic Resonance Imaging, 1993
- Factors influencing the accuracy and precision of velocity‐encoded phase imagingMagnetic Resonance in Medicine, 1992
- MR imaging of coronary artery flow in isolated and in vivo heartsJournal of Magnetic Resonance Imaging, 1991
- The application of phase shifts in NMR for flow measurementMagnetic Resonance in Medicine, 1990
- Measurement of Flow with NMR Imaging Using a Gradient Pulse and Phase Difference TechniqueJournal of Computer Assisted Tomography, 1984
- Untersuchungen am überlebenden SäugethierherzenPflügers Archiv - European Journal of Physiology, 1895