Comparative Evaluation of the Performance of the Abbott Real-Time Human Immunodeficiency Virus Type 1 (HIV-1) Assay for Measurement of HIV-1 Plasma Viral Load following Automated Specimen Preparation
- 1 May 2006
- journal article
- research article
- Published by American Society for Microbiology in Journal of Clinical Microbiology
- Vol. 44 (5) , 1788-91
- https://doi.org/10.1128/jcm.44.5.1788-1791.2006
Abstract
The performance of the new Abbott real-time human immunodeficiency virus type 1 (HIV-1) assay for HIV-1 RNA load determination in plasma was compared to that of the Abbott LCx HIV-1 RNA quantitative assay following automated RNA isolation by the Abbott m1000 extractor. The measured viral loads of 89 clinical specimens differed by mean 0.19 log 10 copies/ml (95% confidence interval, 0.12 to 0.26 log 10 copies/ml). Although the difference in viral load determinations was positively skewed in favor of the LCx assay, it did not reach statistical significance ( P = 0.42). Results were linearly associated ( R 2 = 0.94) and strongly correlated ( R = 0.96). Good performance was observed with HIV-1 subtypes other than B and circulating recombinant forms, although results obtained with two subtype G specimens and one H specimen showed a more substantial difference.Keywords
This publication has 9 references indexed in Scilit:
- HIV‐1 subtypes in Spain: a retrospective analysis from 1995 to 2003HIV Medicine, 2005
- Impact of Human Immunodeficiency Virus Type 1 (HIV-1) Genetic Diversity on Performance of Four Commercial Viral Load Assays: LCx HIV RNA Quantitative, AMPLICOR HIV-1 MONITOR v1.5, VERSANT HIV-1 RNA 3.0, and NucliSens HIV-1 QTJournal of Clinical Microbiology, 2005
- Development, implementation, and trend analysis of real-time PCR tests for the clinical microbiology laboratoryClinical Microbiology Newsletter, 2004
- PCR-based diagnostics for infectious diseases: uses, limitations, and future applications in acute-care settingsThe Lancet Infectious Diseases, 2004
- Comparison of LCx with Other Current Viral Load Assays for Detecting and Quantifying Human Immunodeficiency Virus Type 1 RNA in Patients Infected with the Circulating Recombinant Form A/G (CRF02)Journal of Clinical Microbiology, 2004
- Real-time nucleic acid amplification in clinical microbiologyClinical Microbiology Newsletter, 2004
- Evaluation of the Abbott LCx Quantitative Assay for Measurement of Human Immunodeficiency Virus RNA in PlasmaJournal of Clinical Microbiology, 2002
- Quantification of HIV-1 group M (subtypes A–G) and group O by the LCx HIV RNA quantitative assayJournal of Virological Methods, 2000
- Subtype-specific problems with quantification of plasma HIV-1 RNAAIDS, 1997