Dosimetric accuracy of a staged radiosurgery treatment
- 13 April 2005
- journal article
- research article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 50 (9) , 1991-2002
- https://doi.org/10.1088/0031-9155/50/9/005
Abstract
For large cerebral arteriovenous malformations (AVMs), the efficacy of radiosurgery is limited since the large doses necessary to produce obliteration may increase the risk of radiation necrosis to unacceptable levels. An alternative is to stage the radiosurgery procedure over multiple stages (usually two), effectively irradiating a smaller volume of the AVM nidus with a therapeutic dose during each session. The difference between coordinate systems defined by sequential stereotactic frame placements can be represented by a translation and a rotation. A unique transformation can be determined based on the coordinates of several fiducial markers fixed to the skull and imaged in each stereotactic coordinate system. Using this transformation matrix, isocentre coordinates from the first stage can be displayed in the coordinate system of subsequent stages allowing computation of a combined dose distribution covering the entire AVM. The accuracy of this approach was tested on an anthropomorphic head phantom and was verified dosimetrically. Subtle defects in the phantom were used as control points, and 2 mm diameter steel balls attached to the surface were used as fiducial markers and reference points. CT images (2 mm thick) were acquired. Using a transformation matrix developed with two frame placements, the predicted locations of control and reference points had an average error of 0.6 mm near the fiducial markers and 1.0 mm near the control points. Dose distributions in a staged treatment approach were accurately calculated using the transformation matrix. This approach is simple, fast and accurate. Errors were small and clinically acceptable for Gamma Knife radiosurgery. Accuracy can be improved by reducing the CT slice thickness.Keywords
This publication has 8 references indexed in Scilit:
- A technique to re-establish dose distributions for previously treated brain cancer patients in external beam radiotherapyMedical Dosimetry, 2004
- Comparison of an image registration technique based on normalized mutual information with a standard method utilizing implanted markers in the staged radiosurgical treatment of large arteriovenous malformationsInternational Journal of Radiation Oncology*Biology*Physics, 2003
- Characteristics of sensitometric curves of radiographic filmsMedical Physics, 2003
- Fiducial‐based targeting accuracy for external‐beam radiotherapyMedical Physics, 2002
- Image registration and calculation of a biologically effective dose for multisession radiosurgical treatmentsJournal of Neurosurgery, 2000
- A technique for the quantitative evaluation of dose distributionsMedical Physics, 1998
- An integrated logistic formula for prediction of complications from radiosurgeryInternational Journal of Radiation Oncology*Biology*Physics, 1989
- Design and Testing of a Generalized Reduced Gradient Code for Nonlinear ProgrammingACM Transactions on Mathematical Software, 1978