This paper reports the results of a prospective survey of 266 attempted central venous catheterisations by various routes, evaluating their success rate and incidence of immediate complications and attempts to demonstrate a relationship between patient height in centimetres (H) and ideal catheter length. The overall rate of intrathoracic placement was 230 from 239 catheterisations (96%) after 266 attempts (86%). Of these 230 catheters, 54 terminated in the right atrium (24%). To avoid right atrial placement with its well documented risk of cardiac tamponade, it is recommended that right infraclavicular subclavian catheters are inserted to H/10-2 cm, right internal or external jugular catheters to H/10 cm and left external jugular catheters to H/10 + 4 cm.Keywords
This publication has 13 references indexed in Scilit:
- Cardiac Tamponade from Central Venous Catheters Report of a Case and Review of the English LiteratureAngiology, 1984
- Cardiac tamponade associated with a multilumen central venous catheterCritical Care Medicine, 1984
- Fatal Cardiac TamponadePublished by American Medical Association (AMA) ,1982
- Positioning the Right Atrial CatheterAnesthesiology, 1981
- Percutaneous Cervical Central Venous Line PlacementAnesthesia & Analgesia, 1980
- A prospective study of subclavian vein catheters used exclusively for the purpose of intravenous feedingBritish Journal of Surgery, 1978
- Cardiac tamponade and central venous catheters.BMJ, 1975
- Central venous pressure: Physiological significance and clinical implicationsAmerican Heart Journal, 1973
- Percutaneous catheterisation of the internal jugular veinAnaesthesia, 1969
- The Infraclavicular VenipunctureArchives of Surgery, 1967