Protein recovery from cell debris using rotary and tangential crossflow microfiltration
- 20 July 1995
- journal article
- research article
- Published by Wiley in Biotechnology & Bioengineering
- Vol. 47 (2) , 155-164
- https://doi.org/10.1002/bit.260470206
Abstract
Protein recovery from a bacterial lysate was accomplished using microfiltration membranes in a flat crossflow filter and in a cylindrical rotary filter. Severe membrane fouling yielded relatively low long-term permeate flux values of 10−4–10−3 cm/s (where I cm/s = 3.6 × 104 L/m2 – h). The permeate flux was found to be nearly independent of transmembrane pressure and to increase with increasing shear rate and decreasing solids concentration. The flux increased with shear to approximately the one-third power or greater for the flat filter and the one-half power or greater for the rotary filter; the stronger dependence for the rotary filter is thought to result from Taylor vortices enhancing the back transport of debris carried to the membrane surface by the permeate flow. The average protein transmission or sieving coefficient was measured at approximately 0.6, but considerable scatter in the transmission data was observed. The largest sieving coefficients were obtained for dilute suspensions at high shear rate. The rotary filter provided higher fluxes than did the flat filter for dilute suspensions, but not for concentrated suspensions. © 1995 John Wiley & Sons, Inc.Keywords
This publication has 17 references indexed in Scilit:
- Diagnosis of membrane fouling using a rotating annular filter. 2. Dilute particle suspensions of known particle sizeJournal of Membrane Science, 1993
- Diagnosis of membrane fouling using a rotating annular filter. 1. Cell culture mediaJournal of Membrane Science, 1993
- Theory for Crossflow MicrofiltrationPublished by Springer Nature ,1992
- Crossflow filtration for the separation of inclusion bodies from soluble proteins in recombinant escherichia coli cell lysateJournal of Membrane Science, 1990
- Plasma Filtration in Couette Flow Membrane DevicesArtificial Organs, 1989
- Microfiltration of protein solutions: effect of fouling on rejectionDesalination, 1988
- Dynamic filtration of microbial suspensions using an axially rotating filterJournal of Membrane Science, 1988
- Studies on the separation of intracellular soluble enzymes from bacterial cell debris by tangential flow membrane filtrationBiotechnology Letters, 1985
- Self-diffusion of particles in shear flow of a suspensionJournal of Fluid Mechanics, 1977