High‐resolution, spin‐echo BOLD, and CBF fMRI at 4 and 7 T
Open Access
- 26 September 2002
- journal article
- research article
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 48 (4) , 589-593
- https://doi.org/10.1002/mrm.10252
Abstract
With growing interest in noninvasive mapping of columnar organization and other small functional structures in the brain, achieving high spatial resolution and specificity in fMRI is of critical importance. We implemented a simple method for BOLD and perfusion fMRI with high spatial resolution and specificity. Increased spatial resolution was achieved by selectively exciting a slab of interest along the phase‐encoding direction for EPI, resulting in a reduced FOV and number of phase‐encoding steps. Improved spatial specificity was achieved by using SE EPI acquisition at high fields, where it is predominantly sensitive to signal changes in the microvasculature. Robust SE BOLD and perfusion fMRI were obtained with a nominal in‐plane resolution up to 0.5 × 0.5 mm2 at 7 and 4 Tesla, and were highly reproducible under repeated measures. This methodology enables high‐resolution and high‐specificity studies of functional topography in the millimeter to submillimeter spatial scales of the human brain. Magn Reson Med 48:589–593, 2002.Keywords
This publication has 21 references indexed in Scilit:
- High‐resolution fMRI using multislice partial k‐space GR‐EPI with cubic voxelsMagnetic Resonance in Medicine, 2001
- Functional MRI of the human brain with GRASE-based BOLD contrastMagnetic Resonance in Medicine, 1999
- Optimized outer volume suppression for single‐shot fast spin‐echo cardiac imagingJournal of Magnetic Resonance Imaging, 1998
- MR‐guided biopsy using a T2‐weighted single‐shot Zoom Imaging sequence (Local Look technique)Journal of Magnetic Resonance Imaging, 1998
- High-resolution echo-planar fMRI of human visual cortex at 3.0 teslaNMR in Biomedicine, 1997
- Localized echo-volume imaging methods for functional MRIJournal of Magnetic Resonance Imaging, 1997
- Brain magnetic resonance imaging with contrast dependent on blood oxygenation.Proceedings of the National Academy of Sciences, 1990
- Single‐shot localized echo‐planar imaging (STEAM‐EPI) at 4.7 teslaMagnetic Resonance in Medicine, 1990
- Image reconstruction using POCS, model constraints, and linear prediction theory for the removal of phase, motion, and Gibbs artifacts in magnetic resonance and ultrasound imagingOptical Engineering, 1990
- Inner volume MR imaging: technical concepts and their application.Radiology, 1985