The Molten Carbonate Carbon Dioxide Concentrator: Cathode Performance at High CO 2 Utilization

Abstract
Representative cathode half‐cell polarization data at low inlet cathode concentrations are presented for the MCCDC operated in the fuel‐cell mode. A mathematical model is used to correlate the cathode data and to explain the observed behavior, especially at high utilization. Also presented are representative cathode removal and current efficiency data.

This publication has 0 references indexed in Scilit: