Platelet deposition onto polymeric surfaces during shunting
- 1 March 1993
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 27 (3) , 335-343
- https://doi.org/10.1002/jbm.820270307
Abstract
In an attempt to develop blood‐contacting tubes that can be applied for short‐term uses with a reduced heparin concentration or, ideally, without heparinization, we evaluated the blood compatibility of polymeric materials with a rabbit ex vivo shunt model. The shunt tubes employed were made of silicone, plasticized poly(vinyl chloride) (PVC), and segmented poly(ether urethane) (PU). In addition, two kinds of surface‐modified tube were used: poly(vinyl alcohol) (PVA)‐coated PVC and poly(dimethylacrylamide) (PDMAA)‐grafted PU. The ex vivo shunt results correlated well with protein adsorption and platelet adhesion in vitro. The following order for the extent of platelet deposition was given, irrespective of the blood‐contacting duration: PDMAA‐grafted PU < PVA‐coated PVC < PU < silicone, PVC. It is likely that many platelet aggregates detached from the PVA‐coated PVC surface. For PDMAA‐grafted PU, no trace of detachment of aggregates could be detected on any of the SEM photographs. The number and morphology of blood cells adhered onto the tube surfaces during ex vivo shunting were dependent on the kind of polymer surfaces, the blood exposure time, and the flow rate of blood. © 1993 John Wiley & Sons, Inc.Keywords
This publication has 9 references indexed in Scilit:
- Hydrophilic‐hydrophobic microdomain surfaces having an ability to suppress platelet aggregation and their in vitro antithrombogenicityJournal of Biomedical Materials Research, 1986
- Graft copolymerization of acrylamide onto a polyethylene surface pretreated with glow dischargeMacromolecules, 1986
- The interaction of blood components with PDMS(polydimethylsiloxane) and LDPE (low‐density polyethylene) in a baboon ex vivo arteriovenous shunt modelJournal of Biomedical Materials Research, 1985
- Parallel flow arteriovenous shunt for the ex vivo evaluation of heparinized materialsJournal of Biomedical Materials Research, 1985
- A baboon flow-regulated shunt for the study of small caliber vascular graftsJournal of Surgical Research, 1984
- A canine ex vivo series shunt for evaluating thrombus deposition on polymer surfacesJournal of Biomedical Materials Research, 1984
- Physicochemical characterization and in vivo blood tolerability of cast and extruded biomerJournal of Biomedical Materials Research, 1983
- Activation of human neutrophils with 1-O-hexadecyl/octadecyl-2-acetyl-sn-glycerol-3-phosphorylcholine (platelet activating factor).The Journal of Immunology, 1981
- Flat plate streaming potential investigations: Hydrodynamics and electrokinetic equivalencyJournal of Colloid and Interface Science, 1980