Sensitivity, reproducibility, and accuracy in short tandem repeat genotyping using capillary array electrophoresis.
Open Access
- 1 September 1996
- journal article
- Published by Cold Spring Harbor Laboratory in Genome Research
- Vol. 6 (9) , 893-903
- https://doi.org/10.1101/gr.6.9.893
Abstract
The Human Genome Initiative has increased significantly the rate at which disease-causing genes are being mapped and sequenced. New cost-effective methods to locate the genes and to characterize disease-causing mutations require robust, reproducible, and accurate protocols for measuring DNA fragment lengths. Capillary array electrophoresis (CAE) offers rapid, high-resolution separations, high throughput, and sensitive detection. To assess the utility of CAE for the accumulation of genetic information, we tested both sizing accuracy and reproducibility using 48-capillary prototype systems. Two multiplex PCR allelic ladder standards and several CA-repeat markers were analyzed in > 100 runs. Reproducibility in typing > 8000 genotypes reveals a standard deviation of less than 0.2 bp on these systems under optimized conditions. However, sequence-dependent migration anomalies were observed at most simple sequence loci even when analyzed under denaturing conditions, resulting in a systematic bias in estimated fragment sizes. We show here that, by normalizing results to known typing controls, one can obtain locus-averaged accuracies of < 0.06 bp and normalized results within 1 bp of actual. We detect as little as a 1:30,000 dilution of a DNA quantitation standard stained with highly sensitive intercalating dyes, indicating an 80-zeptomole sensitivity limit. However, to obtain reproducible electrokinetic injection, approximately 200 attomoles of fluorescein-labeled DNA is required. These sensitivity limits, sizing precision, and accuracy, together with the 1-hr run times for 48-96 samples, indicate that CAE is a viable method for high-throughput genetic analysis of simple sequence repeat polymorphisms.Keywords
This publication has 21 references indexed in Scilit:
- Peer Reviewed: Capillary Electrophoresis and Daubert: Time for AdmissionAnalytical Chemistry, 1996
- Anomalous Rapid Electrophoretic Mobility of DNA Containing Triplet Repeats Associated with Human Disease GenesBiochemistry, 1995
- Population survey of the human FMR1 CGG repeat substructure suggests biased polarity for the loss of AGG interruptionsHuman Molecular Genetics, 1995
- Evaluation of an automated DNA profiling system employing multiplex amplification of four tetrameric STR lociInternational journal of legal medicine, 1994
- Capillary electrophoresis of polymerase chain reaction‐amplified products in polymer networks: The case of Kennedy's diseaseElectrophoresis, 1994
- Duchenne/becker muscular dystrophy carrier detection using quantitative PCR and fluorescence‐based strategiesAmerican Journal of Medical Genetics, 1993
- Forensic validation of the STR systems SE 33 and TC 11International journal of legal medicine, 1993
- Electromigration behavior of poly-(L-glutamate) conformers in concentrated polyacrylamide gelsBiopolymers, 1993
- Genetic variation at five trimeric and tetrameric tandem repeat loci in four human population groupsGenomics, 1992
- Microsatellites for linkage analysis of genetic traitsTrends in Genetics, 1992