Sensitivity analysis of respiratory parameter uncertainties: impact of criterion function form and constraints
- 1 August 1990
- journal article
- research article
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 69 (2) , 766-775
- https://doi.org/10.1152/jappl.1990.69.2.766
Abstract
A sensitivity analysis based on weighted least-squares regression is presented to evaluate alternative methods for fitting lumped-parameter models to respiratory impedance data. The goal is to maintain parameter accuracy simultaneously with practical experiment design. The analysis focuses on predicting parameter uncertainties using a linearized approximation for joint confidence regions. Applications are with four-element parallel and viscoelastic models for 0.125- to 4-Hz data and a six-element model with separate tissue and airway properties for input and transfer impedance data from 2-64 Hz. The criterion function form was evaluate by comparing parameter uncertainties when data are fit as magnitude and phase, dynamic resistance and compliance, or real and imaginary parts of input impedance. The proper choice of weighting can make all three criterion variables comparable. For the six-element model, parameter uncertainties were predicted when both input impedance and transfer impedance are acquired and fit simultaneously. A fit to both data sets from 4 to 64 Hz could reduce parameter estimate uncertainties considerably from those achievable by fitting either alone. For the four-element models, use of an independent, but noisy, measure of static compliance was assessed as a constraint on model parameters. This may allow acceptable parameter uncertainties for a minimum frequency of 0.275-0.375 Hz rather than 0.125 Hz. This reduces data acquisition requirements from a 16- to a 5.33-to 8-s breath holding period. These results are approximations, and the impact of using the linearized approximation for the confidence regions is discussed.This publication has 10 references indexed in Scilit:
- Density dependence of respiratory input and transfer impedances in humansJournal of Applied Physiology, 1988
- A theoretical analysis of interrupter technique for measuring respiratory mechanicsJournal of Applied Physiology, 1988
- Human respiratory input impedance from 4 to 200 Hz: physiological and modeling considerationsJournal of Applied Physiology, 1988
- Reliability of parameter estimates from models applied to respiratory impedance dataJournal of Applied Physiology, 1987
- Respiratory resistance with histamine challenge by single-breath and forced oscillation methodsJournal of Applied Physiology, 1986
- Forced oscillatory impedance of the respiratory system at low frequenciesJournal of Applied Physiology, 1986
- Total respiratory input and transfer impedances in humansJournal of Applied Physiology, 1985
- Analysis of errors in parameter estimation with application to physiological systemsAmerican Journal of Physiology-Regulatory, Integrative and Comparative Physiology, 1980
- Respiratory parameter estimation using forced oscillatory impedance dataJournal of Applied Physiology, 1977
- Mechanical Factors in Distribution of Pulmonary VentilationJournal of Applied Physiology, 1956