Wear and Morphology of Ultra-High Molecular Weight Polyethylene Wear Particles from Total Hip Replacements
- 1 September 1996
- journal article
- research article
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 210 (3) , 167-174
- https://doi.org/10.1243/pime_proc_1996_210_409_02
Abstract
The wear rate of ultra-high molecular weight polyethylene total hip replacement components is known to be influenced by various factors such as material and design. However, it is not known if these factors affect the size or morphology of the wear particles. The aim of this study was to compare the polyethylene wear particles from hip replacements of differing bearing materials and designs. Tissues were obtained at the revision surgeries of patients with surface replacements with titanium alloy or cobalt-chrome alloy femoral components up to 51 mm in diameter, and stem-type hip replacements with cobalt-chrome or alumina ceramic femoral components that were 28 or 32 mm in diameter. The polyethylene particles were isolated following tissue digestion and density gradient separation, and then studied by scanning electron microscopy. A computerized image analysis system was used to measure the diameter and length of the particles. The majority of wear particles were submicron in diameter. No systematic differences in size and morphology were found between the groups in this study. The similarity in size and morphology of the wear particles suggested that the same basic wear mechanisms were occurring in these components.Keywords
This publication has 25 references indexed in Scilit:
- Preliminary study of the effect of aging following irradiation on the wear of ultrahigh-molecular-weight polyethyleneThe Journal of Arthroplasty, 1995
- Isolation of predominantly submicron‐sized UHMWPE wear particles from periprosthetic tissuesJournal of Biomedical Materials Research, 1995
- Isolation and characterization of debris in membranes around total joint prostheses.Journal of Bone and Joint Surgery, 1994
- Activity and socket wear in the Charnley low-friction arthroplastyThe Journal of Arthroplasty, 1994
- Radiolucency at the bone-cement interface in total knee replacement. The effects of bone-surface preparation and cement technique.Journal of Bone and Joint Surgery, 1994
- Histologic identification of polyethylene wear debris using Oil Red O stainJournal of Applied Biomaterials, 1993
- The effect of transfer film and surface roughness on the wear of lubricated ultra-high molecular weight polyethyleneClinical Materials, 1993
- Histologic investigations on 33 retrieved Nobelpharma implantsClinical Materials, 1993
- Effect of roughness and sliding speed on the wear and friction of ultra-high molecular weight polyethyleneWear, 1992
- The effect of the surface finish of alumina and stainless steel on the wear rate of UHMW polyethyleneBiomaterials, 1986