Adherence to a strict specimen‐labeling policy decreases the incidence of erroneous blood grouping of blood bank specimens
- 12 November 1997
- journal article
- research article
- Published by Wiley in Transfusion
- Vol. 37 (11-12) , 1169-1172
- https://doi.org/10.1046/j.1537-2995.1997.37111298088047.x
Abstract
BACKGROUND: To assess the effectiveness of a system of preventing incompatible blood transfusions resulting from the misidentification of patient specimens, a prospective analysis of all blood samples submitted to a laboratory was performed. STUDY DESIGN AND METHODS: Incorrectly labeled specimens (rejected samples) were tested for ABO and Rh type, and routine antibody screens were performed. Test results were compared to historic patient data or patient data obtained from subsequently submitted (correctly) labeled specimens. For comparison, all discrepant serologic results from appropriately labeled samples were also recorded. RESULTS: Specimens that failed to meet the criteria for specimen acceptance were 40 times more likely to have a blood grouping discrepancy. CONCLUSION: Strict adherence to the labeling requirements results in a significant decrease in erroneous blood grouping. This would accordingly diminish the likelihood of transfusing out‐of‐group blood components.Keywords
This publication has 4 references indexed in Scilit:
- A cost-effectiveness analysis of the use of a mechanical barrier system to reduce the risk of mistransfusionTransfusion, 1996
- An automated system for bedside verification of the match between patient identification and blood unit identificationTransfusion, 1996
- A report of 104 transfusion errors in New York StateTransfusion, 1992
- Reports of 355 transfusion‐associated deaths: 1976 through 1985Transfusion, 1990