Migration of acetabular components, inserted with and without cement, in one-stage bilateral hip arthroplasty. A controlled, randomized study using roentgenstereophotogrammetric analysis.
- 1 February 1994
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 76 (2) , 185-194
- https://doi.org/10.2106/00004623-199402000-00004
Abstract
Twenty-one patients who had primary osteoarthrosis were managed with a bilateral total hip arthroplasty with insertion of a Charnley femoral component. In each patient, one hip was randomly allocated to have a Harris-Galante acetabular component inserted without cement, and the contralateral hip was treated with an all-polyethylene Charnley acetabular component fixed with cement. The clinical result was satisfactory in all patients. All forty-two hips were followed, with respect to migration of the acetabular component, with use of roentgenstereophotogrammetric analysis for a median of twenty-seven months (range, twenty-three to forty-nine months). Each patient served as his or her own control. Maximum migration in any direction was 1.7 and 2.1 millimeters, and maximum rotation was 2.2 and 2.0 degrees for the Harris-Galante and Charnley acetabular components, respectively. There was no significant difference in migration between the two designs of acetabular components (p = 0.98, p = 0.75, and p = 0.06 for the transverse, longitudinal, and sagittal axes, respectively). However, the Harris-Galante acetabular components rotated significantly more than the Charnley acetabular components around two of the three axes (p = 0.008, p = 0.08, and p = 0.03 for the transverse, longitudinal, and sagittal axes, respectively). The Charnley hip implant has been used clinically for a long time, with successful results.Comparison of new designs of implants with the Charnley prosthesis is therefore important. Roentgenstereophotogrammetric analysis provides a potential for detection of problems with fixation at an early stage rather than after long-term follow-up. No major difference in terms of skeletal fixation was found between the two designs of components after short to medium-term follow-up.Keywords
This publication has 15 references indexed in Scilit:
- A prospective study of 100 consecutive harris-galante porous total hip arthroplasties: 2–5—Year resultsThe Journal of Arthroplasty, 1992
- Early migration of prostheses related to long-term survivorship. Comparison of tibial components in knee replacementThe Journal of Bone and Joint Surgery. British volume, 1992
- Intermittent micromotion inhibits bone ingrowthActa Orthopaedica, 1992
- Results of the Harris-Galante cementless hip prosthesisThe Journal of Bone and Joint Surgery. British volume, 1992
- Survivorship analysis of 1,041 charnley total hip arthroplastiesThe Journal of Arthroplasty, 1990
- The measurement of migration of the acetabular component of hip prosthesesThe Journal of Bone and Joint Surgery. British volume, 1989
- Roentgen stereophotogrammetry: Review of orthopedic applicationsActa Orthopaedica, 1989
- Mechanical loosening of total hip prostheses. A radiographic and roentgen stereophotogrammetric studyThe Journal of Bone and Joint Surgery. British volume, 1986
- Total hip arthroplasty.Journal of Bone and Joint Surgery, 1978
- An Instrument for Insertion of Radiopaque Bone MarkersRadiology, 1974