In vitromeasurements of absolute blood oxygen saturation using pulsed near-infrared photoacoustic spectroscopy: accuracy and resolution
- 7 September 2005
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 50 (18) , 4409-4428
- https://doi.org/10.1088/0031-9155/50/18/011
Abstract
Pulsed photoacoustic spectroscopy was used to measure blood oxygen saturation in vitro. An optical parametric oscillator laser system provided nanosecond excitation pulses over the wavelength range 740-1040 nm which were used to generate photoacoustic signals in a cuvette through which a saline suspension of red blood cells was circulated. The signal amplitude and the effective attenuation coefficient were extracted from the photoacoustic signals as a function of wavelength to provide photoacoustic spectra of the blood. From these, the relative concentrations of oxy- and deoxyhaemoglobin, and therefore blood oxygen saturation (SO2), were determined using forward models of the absorbed energy distribution based on diffusion theory. A standard linear model of the dependence of absorbance on the concentration of chromophores was also used to calculate the blood oxygen saturation from the signal amplitude spectra. The diffusion approximation model was shown to produce the highest accuracy in blood SO2. The photoacoustically determined oxygen saturation was found to have an accuracy of +/-4% SO2 for signal amplitude data and +/-2.5% SO2 for effective attenuation spectra. The smallest change in oxygen saturation that can be measured using this technique was +/-1% SO2.Keywords
This publication has 28 references indexed in Scilit:
- Interrogation of free-space Fabry–Perot sensing interferometers by angle tuningMeasurement Science and Technology, 2003
- Influence of cell shape and aggregate formation on the optical properties of flowing whole bloodApplied Optics, 2003
- Optoacoustic technique for noninvasive monitoring of blood oxygenation: a feasibility studyApplied Optics, 2002
- Photoacoustic imaging of blood vessel equivalent phantomsPublished by SPIE-Intl Soc Optical Eng ,2002
- Local determination of hemoglobin concentration and degree of oxygenation in tissue by pulsed photoacoustic spectroscopyPublished by SPIE-Intl Soc Optical Eng ,2000
- Transduction mechanisms of the Fabry-Perot polymer film sensing concept for wideband ultrasound detectionIEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 1999
- Single scattering by red blood cellsApplied Optics, 1998
- A finite element approach for modeling photon transport in tissueMedical Physics, 1993
- Erythrocyte volume distribution in normal and abnormal subjectsBlood, 1975
- Optical Constants of Water in the 200-nm to 200-μm Wavelength RegionApplied Optics, 1973