Stress distributions within the proximal femur during gait and falls: Implications for osteoporotic fracture
- 1 July 1995
- journal article
- research article
- Published by Springer Nature in Osteoporosis International
- Vol. 5 (4) , 252-261
- https://doi.org/10.1007/bf01774015
Abstract
The rates of fracture at sites with different relative amounts of cortical and trabecular bone (hip, spine, distal radius) have been used to make inferences about the pathomechanics of bone loss and the existence of type I and type II osteoporosis. However, fracture risk is directly related to the ratio of tissue stress to tissue strength, which in turn is dependent not only on tissue composition but also tissue geometry and the direction and magnitude of loading. These three elements determine how the load is distributed within the tissue. As a result, assumptions on the relative structural importance of cortical and trabecular bone, and how these tissues are affected by bone loss, can be inaccurate if based on regional tissue composition and bone density alone. To investigate the structural significance of cortical and trabecular bone in the proximal femur, and how it is affected by bone loss, we determined the stress distributions in a normal and osteoporotic femur resulting from loadings representing: (1) gait; and (2) a fall to the side with impact onto the greater trochanter. A three-dimensional finite element model was generated based on a representative femur selected from a large database of femoral geometries. Stresses were analyzed throughout the femoral neck and intertrochanteric regions. We found that the percentage of total load supported by cortical and trabecular bone was approximately constant for all load cases but differed depending on location. Cortical bone carried 30% of the load at the subcapital region, 50% at the mid-neck, 96% at the base of the neck and 80% at the intertrochanteric region. These values differ from the widely held assumption that cortical bone carries 75% of the load in the femoral neck and 50% of the load at the intertrochanteric region. During gait, the principal stresses were concentrated within the primary compressive system of trabeculae and in the cortical bone of the intertrochanteric region. In contrast, during a fall, the trabecular stresses were concentrated within the primary tensile system of trabeculae with a peak magnitude 4.3 times that present during gait. While the distribution of stress for the osteoporotic femur was similar to the normal, the magnitude of peak stress was increased by between 33% and 45%. These data call into question several assumptions which serve as the basis for theories on the pathomechanics of osteoporosis. In addition, we expect that the insight provided by this analysis will result in the improved development and interpretation of non-invasive techniques for the quantification of in vivo hip fracture risk.Keywords
This publication has 52 references indexed in Scilit:
- Validation of an automated method of three-dimensional finite element modelling of boneJournal of Biomedical Engineering, 1993
- Bone age, mineral density, and fatigue damageCalcified Tissue International, 1993
- Bone quality: A determinant for certain risk factors for bone fragilityCalcified Tissue International, 1993
- Prediction of Femoral Impact Forces in Falls on the HipJournal of Biomechanical Engineering, 1991
- Fracture Prediction for the Proximal Femur Using Finite Element Models: Part II—Nonlinear AnalysisJournal of Biomechanical Engineering, 1991
- Mechanical Properties of Trabecular Bone from the Proximal FemurJournal of Computer Assisted Tomography, 1990
- Fracture of the human femoral neck: Effect of density of the cancellous coreJournal of Biomedical Engineering, 1984
- Finite-element-analysis and experimental investigation in a femur with hip endoprosthesisJournal of Biomechanics, 1983
- The mechanical characteristics of cancellous bone at the upper femoral regionJournal of Biomechanics, 1983
- An evaluation of the approaches of optimization models in the prediction of muscle forces during human gaitJournal of Biomechanics, 1981