Anti-aliased three-dimensional cone-beam reconstruction of low-contrast objects with algebraic methods
- 1 June 1999
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 18 (6) , 519-537
- https://doi.org/10.1109/42.781017
Abstract
This paper examines the use of the algebraic reconstruction technique (ART) and related techniques to reconstruct 3-D objects from a relatively sparse set of cone-beam projections. Although ART has been widely used for cone-beam reconstruction of high-contrast objects, e.g., in computed angiography, the work presented here explores the more challenging low-contrast case which represents a little-investigated scenario for ART. Preliminary experiments indicate that for cone angles greater than 20 degrees, traditional ART produces reconstructions with strong aliasing artifacts. These artifacts are in addition to the usual off-midplane inaccuracies of cone-beam tomography with planar orbits. We find that the source of these artifacts is the nonuniform reconstruction grid sampling and correction by the cone-beam rays during the ART projection-backprojection procedure. A new method to compute the weights of the reconstruction matrix is devised, which replaces the usual constant-size interpolation filter by one whose size and amplitude is dependent on the source-voxel distance. This enables the generation of reconstructions free of cone-beam aliasing artifacts, at only little extra cost. An alternative analysis reveals that simultaneous ART (SART) also produces reconstructions without aliasing artifacts, however, at greater computational cost. Finally, we thoroughly investigate the influence of various ART parameters, such as volume initialization, relaxation coefficient lambda, correction scheme, number of iterations, and noise in the projection data on reconstruction quality. We find that ART typically requires only three iterations to render satisfactory reconstruction results.Keywords
This publication has 32 references indexed in Scilit:
- Algebraic Reconstruction Techniques (ART) for three-dimensional electron microscopy and X-ray photographyPublished by Elsevier ,2004
- The influence of a relaxation parameter on SPECT iterative reconstruction algorithmsPhysics in Medicine & Biology, 1996
- Evaluation of task-oriented performance of several fully 3D PET reconstruction algorithmsPhysics in Medicine & Biology, 1994
- In vivo evaluation of a new system for 3D computerized angiographyPhysics in Medicine & Biology, 1994
- A general cone-beam reconstruction algorithmIEEE Transactions on Medical Imaging, 1993
- Alternatives to voxels for image representation in iterative reconstruction algorithmsPhysics in Medicine & Biology, 1992
- Footprint evaluation for volume renderingACM SIGGRAPH Computer Graphics, 1990
- Algebraic reconstruction in CT from limited viewsIEEE Transactions on Medical Imaging, 1989
- Local basis-function approach to computed tomographyApplied Optics, 1985
- ART: Mathematics and applicationsJournal of Theoretical Biology, 1973