Local, high-frequency analysis of the fields in a mode-stirred chamber
- 1 January 1990
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 32 (1) , 53-58
- https://doi.org/10.1109/15.45250
Abstract
The fields inside a mode-stirred chamber are analyzed by a local plane-wave method. This approach has the advantage of being applicable to nonseparable geometries, for which the more standard modal method of analysis is not possible, and gives insight into the nature of the various contributions to the total field. Results are given for the quality factor and for the fields near the walls of the chamber. The expression for the quality factor agrees with previously published work.Keywords
This publication has 4 references indexed in Scilit:
- The effect of an electrically large stirrer in a mode-stirred chamberIEEE Transactions on Electromagnetic Compatibility, 1989
- A review of electromagnetic compatibility/interference measurement methodologiesProceedings of the IEEE, 1985
- Performance and Analysis of a Reverberating Enclosure with Variable GeometryIEEE Transactions on Electromagnetic Compatibility, 1980
- Use of a Reverberating Enclosure for Measurements of Radiated Power in the Microwave RangeIEEE Transactions on Electromagnetic Compatibility, 1976