Erythrocyte rheology.
Open Access
- 1 September 1985
- journal article
- review article
- Published by BMJ in Journal of Clinical Pathology
- Vol. 38 (9) , 965-977
- https://doi.org/10.1136/jcp.38.9.965
Abstract
Erythrocyte deformability was formerly measured by its contribution to whole blood viscosity. It is now more commonly measured by filtration of erythrocytes through, or aspiration into, pores of 3-5 microns diameter and by the measurement of shear induced erythrocyte elongation using laser diffractometry. Recent improvements in the technology for erythrocyte filtration have included the removal of acute phase reactants from test erythrocyte suspensions, ultrasonic cleaning and reuse of filter membranes, awareness of the importance of mean cell volume as a determinant of flow through 3 microns diameter pores, and the ability to detect subpopulations of less deformable erythrocytes. Measurements of erythrocyte elongation by laser diffractometry, using the Ektacytometer, are also influenced by cell size and need to be corrected for mean cell volume. These advances have greatly improved the sensitivity and specificity of rheological methods for measuring the deformability of erythrocytes and for investigating the mode of action of rheologically active drugs.Keywords
This publication has 116 references indexed in Scilit:
- Interleukin-1 and the Pathogenesis of the Acute-Phase ResponseNew England Journal of Medicine, 1984
- A method for the separation of erythrocytes on the basis of size using counterflow centrifugationAmerican Journal of Hematology, 1984
- Fibrinogen as a Risk Factor for Stroke and Myocardial InfarctionNew England Journal of Medicine, 1984
- Prostacyclin increases filterability of normal and rigidified human red blood cellsin vitroInflammation Research, 1984
- Further characterization of the effects of alpha-1-acid glycoprotein on the passage of human erythrocytes through micropores.Cell Structure and Function, 1984
- An improved method for measuring intracellular electrolytes m erythrocytes and the effects of cold storageClinica Chimica Acta; International Journal of Clinical Chemistry, 1983
- Ein Gerät zur elektrischen Messung der Verformbarkeit von Erythrozyten - A Device for the Electrical Measurement of the Deformability of Red Blood CellsBiomedizinische Technik/Biomedical Engineering, 1983
- Deformability of isolated red blood cell membranesBiochimica et Biophysica Acta (BBA) - Biomembranes, 1982
- Production of Single Pore Membranes for the Measurement of Red Blood Cell Deformability - Produktion von Einzelloch-Membranen zur Messung des Verformungsvermögens von roten BlutkörperchenBiomedizinische Technik/Biomedical Engineering, 1981
- A Convenient and Reproducible Filtration Technique for the Determination of Erythrocyte FlexibilityBritish Journal of Haematology, 1976