Polyethylene wear debris and tissue reactions in knee as compared to hip replacement prostheses
- 1 September 1994
- journal article
- research article
- Published by Wiley in Journal of Applied Biomaterials
- Vol. 5 (3) , 185-190
- https://doi.org/10.1002/jab.770050302
Abstract
Differences in bearing surface conformity and wear mechanisms suggest that the polyethylene (PE) wear debris generated by total knee replacement (TKR) prostheses should be different than that in total hip replacement prostheses (THR). To address this issue, PE wear debris and the cellular response in periprosthetic tissues from 19 failed TKRs was compared to that from 24 failed THRs using polarized light microscopy and a semiquantitative grading system. The foreign-body inflammatory reaction in the THR cases was characterized by plump macrophages with a diffuse cytoplasmic birefringence when examined under polarized light, indicating the presence of multiple submicron particles of PE. The majority of the PE particles were 10 μm. The foreign-body inflammatory reaction in the TKR cases was characterized by giant cells with fewer macrophages. In the TKR specimens, the size range of PE particles was broader than in the hips. PE particles between 2 and 20 μm were frequent in TKR specimens; particles <1 μm in length were less common than in the THR specimens. Diffuse cytoplasmic birefringence was not a characteristic of the TKR cases. These histologic differences were so consistently distinct that the source of the specimen (i.e., from a THR or TKR) could be blindly determined by light microscopy. The size distribution of the PE wear particles in these cases indicate that THRs generate a higher number of submicron PE particles and relatively few large particles while TKRs generate a broader range of particles that includes fewer submicron particles. The observed differences in the cellular responses is likely a direct result of the differences in the spectrum of PE wear particles. These differences may in part account for differences in periprosthetic bone resorption and loosening in TKRs as compared to THRs. © 1994 John Wiley & Sons, Inc.Keywords
This publication has 24 references indexed in Scilit:
- Light microscopic identification of submicron polyethylene wear debrisJournal of Applied Biomaterials, 1993
- Histologic identification of polyethylene wear debris using Oil Red O stainJournal of Applied Biomaterials, 1993
- Autopsy studies of the bone-cement interface in well-fixed cemented total hip arthroplastiesThe Journal of Arthroplasty, 1993
- Periprosthetic bone loss in total hip arthroplasty. Polyethylene wear debris and the concept of the effective joint space.Journal of Bone and Joint Surgery, 1992
- Wear of Polyethylene in Total Joint Replacements Observations From Retrieved PCA Knee ImplantsClinical Orthopaedics and Related Research, 1992
- The Mechanism of Loosening of Cemented Acetabular Components in Total Hip ArthroplastyClinical Orthopaedics and Related Research, 1992
- Polyethylene failure in two total knees: Wear of thin, metal-backed PCA tibial componentsActa Orthopaedica, 1990
- Polyethylene failure in a PCA unicompartmental knee prosthesisActa Orthopaedica, 1990
- Wear of ultra-high-molecular-weight polyethylene components of 90 retrieved knee prosthesesThe Journal of Arthroplasty, 1988
- Granulomatous Reaction and Cystic Bony Destruction Associated with High Wear Rate in a Total Knee ProsthesisClinical Orthopaedics and Related Research, 1985