NON-INVASIVE MONITORING OF INTRACRANIAL PRESSURE-FACT OR FANCY?
- 12 November 2008
- journal article
- research article
- Published by Wiley in Developmental Medicine and Child Neurology
- Vol. 29 (3) , 320-326
- https://doi.org/10.1111/j.1469-8749.1987.tb02485.x
Abstract
Ladd and Wright fontanelle pressure meters were applied to the heads of 18 babies, and simultaneously the intracranial pressure was monitored directly. Increasing the force with which the meters were applied caused a linear increase in registered fontanelle pressure. No universally optimal application force could be determined. To obviate this, application force was increased until the fontanelle pressure was calibrated with directly measured intracranial pressure. Subsequent variations in intracranial pressure were significantly correlated to fontanelle pressure, but not closely enough for clinical reliability. The correlation was similar if the meter was affixed instead directly to the scalp with collodion gel, and the clinical reliability improved. Applanation fontanometers are strongly affected by variations in the method by which they are applied and may not be a reliable reflection of intracranial pressure. If directly affixed to the scalp, however, they may yield clinically useful data.This publication has 24 references indexed in Scilit:
- THE PRESSURE-VOLUME CURVE OF THE CEREBROSPINAL FLUID SPACE IN DOGSActa Neurologica Scandinavica, 2009
- Intracranial pressure estimation by palpation of the anterior fontanelle.Archives of Disease in Childhood, 1987
- Cerebrospinal fluid pressure during post haemorrhagic ventricular dilatation in newborn infants.Archives of Disease in Childhood, 1985
- Medical management of raised intracranial pressure after severe birth asphyxia.Archives of Disease in Childhood, 1985
- Continuous and intermittent measurement of intracranial pressure by Ladd monitorThe Journal of Pediatrics, 1983
- Measurement of intracranial pressure using the Ladd intracranial pressure monitorThe Journal of Pediatrics, 1981
- MEASUREMENT OF INTRACRANIAL PRESSURE VIA THE ANTERIOR FONTANELLEThe Kurume Medical Journal, 1978
- Non‐invasive Method for Measuring Intracranial Pressure in Normal Newborn InfantsDevelopmental Medicine and Child Neurology, 1977
- Methods of measuring intracranial pressure via the fontanelle without punctureJournal of Neurology, Neurosurgery & Psychiatry, 1974
- OBSERVATIONS ON THE CEREBROSPINAL FLUID PRESSURE ON SIMULTANEOUS VENTRICULAR AND LUMBAR PUNCTURESJournal of Neurology, Neurosurgery & Psychiatry, 1938