Scintigraphic abnormalities in patients with painful hip replacements treated conservatively
- 1 June 1992
- journal article
- Published by Oxford University Press (OUP) in The British Journal of Radiology
- Vol. 65 (774) , 491-494
- https://doi.org/10.1259/0007-1285-65-774-491
Abstract
A retrospective review of the scintigraphic appearances of 98 painful hip replacements was made. 16 patients (16%) underwent revision surgery whereas in the remaining 82 hips (84%), symptoms settled with conservative management. 73 of these (89%) had at least one area of increased activity on delayed diphosphonate scintigraphy with 27% having increased activity in three or more areas around the femoral component. Hips with increased activity at the lesser trochanter and tip were less likely to undergo spontaneous resolution of symptoms. Uncemented prostheses were more likely to have multiple areas of increased activity. Abnormalities in dynamic bone scintigraphy and gallium studies were also seen in patients whose symptoms resolved without surgery. Whereas a normal bone scintigram indicates that loosening or infection is most unlikely, the presence of increased activity does not necessarily indicate a need for revision surgery, even when multiple areas are present. A period of conservative management should be considered before operative intervention is undertaken.Keywords
This publication has 10 references indexed in Scilit:
- Cemented total hip prosthesis: radiographic and scintigraphic evaluation.Radiology, 1989
- A simple method of identifying loosening or infection of hip prostheses in nuclear medicineNuclear Medicine Communications, 1989
- Asymptomatic total hip prosthesis: natural history determined using Tc-99m MDP bone scans.Radiology, 1986
- 99Tcm-MDP, 67Ga-citrate and 111In-leucocytes for detecting prosthetic hip infectionNuclear Medicine Communications, 1986
- Sequential use of technetium 99m MDP and gallium 67 citrate imaging in the evaluation of painful total hip replacementThe British Journal of Radiology, 1980
- Technetium 99m methylene diphosphonate scanning in Thompson hemiarthroplastiesThe British Journal of Radiology, 1980
- The Painful Hip Prosthesis: Value of Nuclear Imaging in the Diagnosis of Late ComplicationsClinical Nuclear Medicine, 1980
- 99mTc-Methylene Diphosphonate Bone Imaging in the Evaluation of Total Hip ProsthesesRadiology, 1979
- Radionuclide Bone Imaging as a Means of Differentiating Loosening and Infection in Patients with a Painful Total Hip ProsthesisRadiology, 1979
- 99mTc-PP and67Ga Imaging Following Insertion of Orthopedic DevicesRadiology, 1979