Abstract
In recent years, the sophistication and complexity of clinical treatment planning and treatment planning systems has increased significantly, particularly including three-dimensional (3D) treatment planning systems, and the use of conformal treatment planning and delivery techniques. This has led to the need for a comprehensive set of quality assurance (QA) guidelines that can be applied to clinical treatment planning. This document is the report of Task Group 53 of the Radiation Therapy Committee of the American Association of Physicists in Medicine. The purpose of this report is to guide and assist the clinical medical physicist in developing and implementing a comprehensive but viable program of quality assurance for modern radiotherapy treatment planning. The scope of the QA needs for treatment planning is quite broad, encompassing image-based definition of patient anatomy, 3D beam descriptions for complex beams including multileaf collimator apertures, 3D dose calculation algorithms, and complex plan evaluation tools including dose volume histograms. The Task Group recommends an organizational framework for the task of creating a QA program which is individualized to the needs of each institution and addresses the issues of acceptance testing, commissioning the planning system and planning process, routine quality assurance, and ongoing QA of the planning process. This report, while not prescribing specific QA tests, provides the framework and guidance to allow radiation oncology physicists to design comprehensive and practical treatment planning QA programs for their clinics.Keywords
This publication has 50 references indexed in Scilit:
- Field shaping for three-dimensional conformal radiation therapy and multileaf collimationSeminars in Radiation Oncology, 1995
- Quality assessment of medical decision making in radiation oncology: variability in target volume delineation for brain tumoursRadiotherapy and Oncology, 1993
- Automatic generation of beam aperturesMedical Physics, 1993
- The Risks of SoftwareScientific American, 1992
- Integration of multimodality imaging data for radiotherapy treatment planningInternational Journal of Radiation Oncology*Biology*Physics, 1991
- Positional accuracy of isodose lines as a function of dose matrix resolutionPhysics in Medicine & Biology, 1990
- Generation of photon energy deposition kernels using the EGS Monte Carlo codePhysics in Medicine & Biology, 1988
- Dose intercomparison at the radiotherapy centers in The Netherlands. 2. Accuracy of locally applied computer planning systems for external photon beamsRadiotherapy and Oncology, 1988
- Software safety: why, what, and howACM Computing Surveys, 1986