Ocular Reduction in EEG Signals Based on Adaptive Filtering, Regression and Blind Source Separation
Open Access
- 5 November 2008
- journal article
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 37 (1) , 176-191
- https://doi.org/10.1007/s10439-008-9589-6
Abstract
Quantitative electroencephalographic (EEG) analysis is very useful for diagnosing dysfunctional neural states and for evaluating drug effects on the brain, among others. However, the bidirectional contamination between electrooculographic (EOG) and cerebral activities can mislead and induce wrong conclusions from EEG recordings. Different methods for ocular reduction have been developed but only few studies have shown an objective evaluation of their performance. For this purpose, the following approaches were evaluated with simulated data: regression analysis, adaptive filtering, and blind source separation (BSS). In the first two, filtered versions were also taken into account by filtering EOG references in order to reduce the cancellation of cerebral high frequency components in EEG data. Performance of these methods was quantitatively evaluated by level of similarity, agreement and errors in spectral variables both between sources and corrected EEG recordings. Topographic distributions showed that errors were located at anterior sites and especially in frontopolar and lateral–frontal regions. In addition, these errors were higher in theta and especially delta band. In general, filtered versions of time-domain regression and of adaptive filtering with RLS algorithm provided a very effective ocular reduction. However, BSS based on second order statistics showed the highest similarity indexes and the lowest errors in spectral variables.Keywords
This publication has 27 references indexed in Scilit:
- Enhanced detection of artifacts in EEG data using higher-order statistics and independent component analysisNeuroImage, 2007
- A fully automated correction method of EOG artifacts in EEG recordingsClinical Neurophysiology, 2007
- A Model-Based Objective Evaluation of Eye Movement Correction in EEG RecordingsIEEE Transactions on Biomedical Engineering, 2006
- Mutual Information Function Assesses Autonomic Information Flow of Heart Rate Dynamics at Different Time ScalesIEEE Transactions on Biomedical Engineering, 2005
- Automatic correction of ocular artifacts in the EEG: a comparison of regression-based and component-based methodsPublished by Elsevier ,2004
- Optimization of an independent component analysis approach for artifact identification and removal in magnetoencephalographic signalsClinical Neurophysiology, 2004
- An Information-Maximization Approach to Blind Separation and Blind DeconvolutionNeural Computation, 1995
- Ocular artifacts in recording EEGs and event-related potentials II: Source dipoles and source componentsBrain Topography, 1993
- Artifact processing in topographic mapping of electroencephalographie activity in neuropsychopharmacologyPsychiatry Research: Neuroimaging, 1992
- A Solution for Reliable and Valid Reduction of Ocular Artifacts, Applied to the P300 ERPPsychophysiology, 1986