Analysis of the Morphology of the Unipolar Endocardial Paced Evoked Response
- 1 March 1990
- journal article
- review article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 13 (3) , 302-313
- https://doi.org/10.1111/j.1540-8159.1990.tb02044.x
Abstract
In a retrospective study we analyzed the unipolar endocardial evoked response signal (ERS) of 103 patients prior to pacemaker implantation. The objective of this study was to give a complete description of the ERS morphology and to evaluate influences on this morphology of both various electrode characteristics and pacing rate. In addition, spontaneous endocardial signals were studied. The results demonstrate that acute leads had both higher R wave and T wave amplitudes and a faster downslope of the T wave. In the acute leads those with porous titanium carbon coated tips showed a more pronounced T wave. Pacing rate influences the R wave amplitude and the stimulus to T wave interval. Both stimulus to maximum and stimulus to minimum T wave interval show an exponential correlation with the stimulus interval. The interval between maximum and minimum of the T wave and the absolute amplitude of T wave are not influenced by rate. Although there were significant correlations of the spontaneous endocardial signal with the ERS, the predictive value of the spontaneous signal for the ERS morphology is low. Prospective studies will be necessary to confirm the findings in this study.Keywords
This publication has 14 references indexed in Scilit:
- Improved Rate Responsive Algorithm in QT Driven Pacemakers—Evaluation of Initial Response to ExercisePacing and Clinical Electrophysiology, 1989
- Determination of Myocardial Depolarization and Repolarization Times Using the Unipolar Ventricular Evoked Potential: Contrasting Effects of Stimulus Interval and Isoprenaline in the Isolated Perfused Rahhit HeartPacing and Clinical Electrophysiology, 1989
- Nonlinear Relationship Between Pacing and Evoked QT IntervalsPacing and Clinical Electrophysiology, 1988
- Reliability of Evoked Endocardial T‐wave Sensing in 1,500 Pacemaker PatientsPacing and Clinical Electrophysiology, 1986
- Reliability of the Evoked Response in Determining the Paced Ventricular Rate and Performance of the QT or Rate Responsive (TX) PacemakerPacing and Clinical Electrophysiology, 1985
- An exponential formula for heart rate dependence of QT interval during exercise and cardiac pacing in humans: Reevaluation of Bazett's formulaThe American Journal of Cardiology, 1984
- The Use of QT Interval to Determine Pacing Rate: Early Clinical ExperiencePacing and Clinical Electrophysiology, 1983
- The Ventricular Endocardial Paced Evoked ResponsePacing and Clinical Electrophysiology, 1983
- Relation between QT interval and heart rate. New design of physiologically adaptive cardiac pacemaker.Heart, 1981
- Autodiagnostic Pacemaker*Pacing and Clinical Electrophysiology, 1979