Computer-Assisted Laser Scanning and Video Microscopy for Analysis of Cryptosporidium parvum Oocysts in Soil, Sediment, and Feces
- 1 February 1997
- journal article
- research article
- Published by American Society for Microbiology in Applied and Environmental Microbiology
- Vol. 63 (2) , 724-733
- https://doi.org/10.1128/aem.63.2.724-733.1997
Abstract
A computer-assisted laser scanning microscope equipped for confocal laser scanning and color video microscopy was used to examine Cryptosporidium parvum oocysts in two agricultural soils, a barnyard sediment, and calf fecal samples. An agar smear technique was developed for enumerating oocysts in soil and barnyard sediment samples. Enhanced counting efficiency and sensitivity (detection limit, 5.2 x 10(sup2) oocysts(middot)g [dry weight](sup-1)) were achieved by using a semiautomatic counting procedure and confocal laser scanning microscopy to enumerate immunostained oocysts and fragments of oocysts in the barnyard sediment. An agarose-acridine orange mounting procedure was developed for high-resolution confocal optical sectioning of oocysts in soil. Stereo images of serial optical sections revealed the three-dimensional spatial relationships between immunostained oocysts and the acridine orange-stained soil matrix material. In these hydrated, pyrophosphate-dispersed soil preparations, oocysts were not found to be attached to soil particles. A fluorogenic dye permeability assay for oocyst viability (A. T. Campbell, L. J. Robertson, and H. V. Smith, Appl. Environ. Microbiol. 58:3488-3493, 1992) was modified by adding an immunostaining step after application of the fluorogenic dyes propidium iodide and 4(prm1),6-diamidino-2-phenylindole. Comparison of conventional color epifluorescence and differential interference contrast images on one video monitor with comparable black-and-white laser-scanned confocal images on a second monitor allowed for efficient location and interpretation of fluorescently stained oocysts in the soil matrix. This multi-imaging procedure facilitated the interpretation of the viability assay results by overcoming the uncertainties caused by matrix interference and background fluorescence.Keywords
This publication has 25 references indexed in Scilit:
- Applications of laser scanning microscopy for analysis of aquatic microhabitatsMicroscopy Research and Technique, 1996
- Fully automatic determination of soil bacterium numbers, cell volumes, and frequencies of dividing cells by confocal laser scanning microscopy and image analysisApplied and Environmental Microbiology, 1995
- A Massive Outbreak in Milwaukee of Cryptosporidium Infection Transmitted through the Public Water SupplyNew England Journal of Medicine, 1994
- The intrarhabdomal filters in the retinas of mantis shrimpsVision Research, 1994
- Power and limits of laser scanning confocal microscopyBiology of the Cell, 1994
- Routine monitoring of Cryptosporidium oocysts in water using flow cytometryJournal of Applied Bacteriology, 1993
- In vitroexcystation ofCryptosporidium parvumParasitology, 1993
- Efficiency of sand filtration for removing cryptosporidium oocysts from waterJournal of Medical Microbiology, 1990
- Large Community Outbreak of Cryptosporidiosis Due to Contamination of a Filtered Public Water SupplyNew England Journal of Medicine, 1989
- Occurrence of Cryptosporidium Oocysts in Sewage Effluents and Selected Surface WatersJournal of Parasitology, 1987