Reduction in intraocular pressure after laser in situ keratomileusis
- 1 February 2001
- journal article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 27 (2) , 303-309
- https://doi.org/10.1016/s0886-3350(00)00782-3
Abstract
Tonometer at the central (Tcenter) and nasal (Tnasal) areas of the cornea before and after LASIK. The Tcenter and Tnasal IOP between baseline and 1, 3, and 6 months postoperatively was compared. The correlation between ablation depth, amount of treatment, refractive change, and change in central corneal thickness and Tcenter change was evaluated. Results: Six months after LASIK, Tcenter IOP decreased 3.9 mm Hg (25.2%) and Tnasal IOP decreased 2.0 mm Hg (12.7%) (P < .001, P = .02, respectively). The Tnasal measurement was 1.8 mm Hg higher than the Tcenter measurement (P < .001). Significant correlation between each corneal parameter and the Tcenter reduction at 1 month did not continue to 6 months (P gt; .05). Conclusion: At each follow-up, Tnasal IOP was statistically lower than at baseline, although the reduction was not as great as that of Tcenter IOP. A 2 to 3 mm Hg drop in Tnasal up to 6 months after LASIK should be expected. An alternative would be to measure IOP with the Tono-Pen® on the nasal side to fit the tip to the relatively unchanged nasal side of the cornea....Keywords
This publication has 15 references indexed in Scilit:
- Corneal Thickness in Ocular Hypertension, Primary Open-angle Glaucoma, and Normal Tension GlaucomaArchives of Ophthalmology (1950), 1999
- Correlation of intraocular pressure and central corneal thickness in normal myopic eyes and after laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 1998
- Intraocular pressure change measured by Goldmann tonometry after laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 1998
- Central Corneal Thickness in Normal, Glaucomatous, and Ocular Hypertensive EyesArchives of Ophthalmology (1950), 1997
- Accuracy of Goldmann tonometry after refractive surgeryJournal of Cataract & Refractive Surgery, 1997
- The Effect of Excimer Laser Photorefracti*ve Keratectomy on Intraocular Pressure Measurements Using the Goldmann Applanati-on TonometerOphthalmology, 1997
- Reduction in Intraocular Pressure after Excimer Laser Photorefractive KeratectomyOphthalmology, 1997
- Six-month results of the Multicenter Phase I Study of Excimer Laser Myopic KeratomileusisJournal of Cataract & Refractive Surgery, 1994
- The Effect of Corneal Thickness on Applanation TonometryAmerican Journal of Ophthalmology, 1993
- APPLANATION TONOMETRY AND CENTRAL CORNEAL THICKNESSActa Ophthalmologica, 1975