A Quantitative Investigation of Structure-Function Relationships in a Tendon Fascicle Model
- 1 December 1999
- journal article
- research article
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 121 (6) , 598-604
- https://doi.org/10.1115/1.2800859
Abstract
These studies sought to investigate quantitative relationships between the complex composite structure and mechanical properties of tendon. The isolated mouse tail tendon fascicle was chosen as an appropriate model for these so-called “structure-function” investigations. Specifically, collagen fibril diameters and mechanical properties were measured in fascicles from immature (3 week) control, adult (8 week) control, and adult (8 week) Mov13 transgenic mice. Results demonstrated a moderate correlation between mean fibril diameter and fascicle stiffness (r = 0.73, p = 0.001) and maximum load (r = 0.75, p < 0.001), whereas a weak correlation with fascicle modulus (r = 0.39, p = 0.11) and maximum stress (r = 0.48, p = 0.04). An analysis of pooled within-group correlations revealed no strong structure-function trends evidenced at the local or group level, indicating that correlations observed in the general structure-function analyses were due primarily to having three different experimental groups, rather than significant correlations of parameters within the groups.Keywords
This publication has 25 references indexed in Scilit:
- Soft‐tissue “flaws” are associated with the material properties of the healing rabbit medial collateral ligamentJournal of Orthopaedic Research, 1995
- A new optical system for the determination of deformations and strains: Calibration characteristics and experimental resultsJournal of Biomechanics, 1994
- Matrix Macromolecules That Affect the Viscoelasticity of CalfskinJournal of Biomechanical Engineering, 1994
- The effects of strain rate on the properties of the medial collateral ligament in skeletally immature and mature rabbits: A biomechanical and histological studyJournal of Orthopaedic Research, 1990
- The Effects of Temperature on the Viscoelastic Properties of the Rabbit Medial Collateral LigamentJournal of Biomechanical Engineering, 1990
- Collagen Fibrillogenesis in Situ.Annals of the New York Academy of Sciences, 1990
- The Effects of Immobilization on the Ultrastructure and Mechanical Properties of the Medial Collateral Ligament of RatsClinical Orthopaedics and Related Research, 1986
- The Effect of a Lathyritic Diet on the Sensitivity of Tendon to Strain RateJournal of Biomechanical Engineering, 1985
- Age-Dependent Influence of Strain Rate on the Tensile Failure of Rat-Tail TendonJournal of Biomechanical Engineering, 1983
- Quantitative electron microscope observations of the collagen fibrils in rat‐tail tendonBiopolymers, 1977