Assessment of the “long sheath” technique for percutaneous aortic balloon valvuloplasty
- 1 February 1990
- journal article
- research article
- Published by Wiley in Catheterization and Cardiovascular Diagnosis
- Vol. 19 (2) , 129-135
- https://doi.org/10.1002/ccd.1810190213
Abstract
A 100 cm‐long 16.5 F valvuloplasty catheter introducer was assessed as an adjunct for percutaneous transluminal aortic valvuloplasty (PTAV) via the femoral artery in 31 patients with severe aortic stenosis. Observed improvements in peak systolic gradient (81.6 ± 29.9 mm Hg vs. 35.5 ± 16.0 mm Hg, P < 0.000001) and aortic valve area (0.6 ± 0.4 cm2 vs. 1.0 ± 0.6 cm2, P < 0.00001) were similar to those achieved in a control group (C) of 17 patients in which no femoral sheath was used. However, a shorter procedure duration (211 ± 81 min vs. 117 ± 30 min, P < 0.001) and a reduced rate of vascular complications at the femoral puncture site (41% vs. 6.5%) were observed in patients in whom the long sheath (LS) technique was used. The frequency of other PTAV‐related complications was comparable (C = 35%, LS = 29%, P = n.s.). Other technical advantages of this device are: 1) prevention of looping and bending of the balloon catheter in tortuous vessels and easy positioning of the balloon across the aortic orifice provided by the LS trackability, 2) stabilisation of the balloon during inflation, 3) monitoring of supravalvular aortic pressure provided by the side‐arm of the LS and reliable measurement of systolic gradient, and 4) the ability to perform aortograms without the need of another catheter in the ascending aorta. Thus, in our experience, the long sheath technique is a valuable adjunct for PTAV.Keywords
This publication has 12 references indexed in Scilit:
- Lack of sustained clinical improvement in an elderly population after percutaneous aortic valvuloplastyThe American Journal of Cardiology, 1988
- Percutaneous balloon valvuloplasty for calcific aortic stenosis. A treatment 'sine cure'?European Heart Journal, 1988
- The “Long‐Sheath” Technique in Percutaneous Aortic Balloon ValvuloplastyJournal of Interventional Cardiology, 1988
- Percutaneous transluminal aortic valvuloplasty: indications and results in adult aortic stenosisEuropean Heart Journal, 1988
- Percutaneous balloon dilatation of calcific aortic valve stenosis: anatomical and haemodynamic evaluation.Heart, 1988
- Percutaneous aortic balloon dilatation for calcific aortic stenosis in elderly patients: immediate haemodynamic results and short-term follow up.Heart, 1987
- Constrictive pericarditis due to acute rheumatic feverEuropean Heart Journal, 1987
- Results of percutaneous catheter valvuloplasty for calcified aortic stenosis in the elderlyEuropean Heart Journal, 1987
- Percutaneous transluminal balloon valvuloplasty of adult aortic stenosis: Report of 92 casesJournal of the American College of Cardiology, 1987
- Assessment of left ventricular and aortic valve function after aortic balloon valvuloplasty in adult patients with critical aortic stenosis.Circulation, 1987