Use of a Paracorporeal Pneumatic Ventricular Assist Device for Postoperative Cardiogenic Shock in Two Children with Complex Cardiac Lesions
- 1 October 1988
- journal article
- research article
- Published by Wiley in Artificial Organs
- Vol. 12 (5) , 423-430
- https://doi.org/10.1111/j.1525-1594.1988.tb02797.x
Abstract
Pneumatic ventricular assist device (VAD) was utilized for cardiogenic shock after intracardiac operation in two children with complex cardiac anomalies based with single ventricle. In the first case (a 10‐year‐old), after a modified Fontan operation, VAD was placed between the functional left atrium and ascending aorta, serving as a “artificial single ventricle” with neither pumping chamber nor artificial support in the right side of the heart. The systemic circulation was maintained by keeping relatively high central venous pressure. In another child (a 3‐year‐old) who underwent repair of incompetent atrioventricular valve leaving intracardiac lesions, VAD was placed between the common atrium and ascending aorta, serving as a pump for both pulmonary and systemic circulation with regulation of pulmonary blood flow through an aortopulmonary Gore‐Tex shunt. The circulatory assist with VAD was utilized for 5 and 6 days, respectively. Although weaning from the device was not feasible in both patients because of the pulmonary dysfunction, these experience showed the possible use of VAD for cardiogenic shock after surgery in patients with complex cardiac anomalies.Keywords
This publication has 19 references indexed in Scilit:
- Modified Fontan operation for single ventricle with common atrium and abnormal systemic venous drainage: Usefulness of an additional superior vena cava to pulmonary artery anastomosisPediatric Cardiology, 1987
- Extracorporeal membrane oxygenation for postoperative cardiac support in childrenThe Journal of Thoracic and Cardiovascular Surgery, 1986
- Mechanical support of the circulation followed by cardiac transplantationThe Journal of Thoracic and Cardiovascular Surgery, 1986
- Use of a venous assist device after repair of complex lesions of the right heartJournal of the American College of Cardiology, 1986
- Experience with the Fontan procedureThe Journal of Thoracic and Cardiovascular Surgery, 1984
- Intra-aortic balloon pumping in infants and children.Circulation, 1983
- Extrathoracically adjustable pulmonary artery bandingThe Journal of Thoracic and Cardiovascular Surgery, 1983
- Artificial hearts and blood pumps in the treatment of profound heart failure.Circulation, 1983
- Experimental evaluation of atrial function in right atrium-pulmonary artery conduit operation for tricuspid atresiaThe Journal of Thoracic and Cardiovascular Surgery, 1981