Vertical Shear Fractures of the Medial Malleolus: A Biomechanical Study of Five Internal Fixation Techniques
- 1 September 1994
- journal article
- research article
- Published by SAGE Publications in Foot & Ankle International
- Vol. 15 (9) , 483-489
- https://doi.org/10.1177/107110079401500905
Abstract
Fifty embalmed human tibias were osteotomized to create a simulated vertical shear (supination-adduction) fracture of the medial malleolus and were stabilized using one of five internal fixation techniques. In offset axial testing, which simulated supination-adduction loading, the fixation strength of tibias stabilized with either cortical or cancellous lag screws placed perpendicular to the osteotomy was over five times greater than the strength of those treated with an antiglide plate and nearly two and a half times greater than those treated with cancellous lag screws placed oblique to the osteotomy. The tibias stabilized with cancellous lag screws placed perpendicular to the osteotomy exhibited twice the fixation strength of the tibias stabilized with an antiglide plate and distal lag screw. The tibias stabilized with an antiglide plate and distal lag screw and perpendicularly placed cortical or cancellous lag screws demonstrated three times greater resistance to displacement to the applied supination-adduction load than those stabilized with an antiglide plate alone. In offset transverse testing, to simulate loading in external rotation, the mean failure load of the tibias stabilized with cancellous lag screws placed perpendicular to the osteotomy was over two and a half times greater than those stabilized with an antiglide plate and distal lag screw. No significant differences were observed in the resistance to displacement for these tests. These results support the use of lag screws placed perpendicular to the fracture surface for stabilization of vertical shear fractures of the medial malleolus and indicate that the use of an antiglide plate, with or without a distal lag screw, does not offer any advantage over lag screw fixation.Keywords
This publication has 14 references indexed in Scilit:
- The posterior antiglide plate for fixation of fractures of the lateral malleolusInjury, 1992
- Internal Fixation of Femoral Neck FracturesClinical Orthopaedics and Related Research, 1991
- Manual of INTERNAL FIXATIONPublished by Springer Nature ,1991
- Reduction with PlatesPublished by Springer Nature ,1989
- A prospective, randomized study of the management of severe ankle fractures.Journal of Bone and Joint Surgery, 1985
- Operative Treatment of Ankle FracturesActa Orthopaedica, 1981
- THE TREATMENT OF UNSTABLE ANKLE FRACTURESThe Journal of Bone and Joint Surgery. British volume, 1974
- Changes in Trabecular Pattern of the Upper End of the Femur as an Index of OsteoporosisJournal of Bone and Joint Surgery, 1970
- Density of fresh and embalmed human compact and cancellous boneAmerican Journal of Physical Anthropology, 1968
- Effect of embalming on the mechanical properties of beef boneJournal of Applied Physiology, 1964