Electromyogram (EMG) recordings from the subscapularis muscle: Description of a technique
- 1 January 1990
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 8 (1) , 151-153
- https://doi.org/10.1002/jor.1100080120
Abstract
Operative treatments for recurrent dislocation of the shoulder usually focus on the subscapularis muscle because it is supposed to contribute to the joint stability. It is of clinical interest to record the EMG from the subscapularis muscle in order to interpret its function. The purpose of the present study was to describe a safe and reliable route to reach the muscle, deeply located between the scapula and the thoracic cage, with fine‐wire EMG electrodes. Twenty‐four shoulders were investigated in 12 volunteers. A hypodermic needle containing bipolar fine‐wire electrodes was inserted in the posterior axillary line with the subjects in the supine position, and the arm held in an abducted and externally rotated position. Three criteria confirmed the location of the electrodes: experience of periosteal pain when the needle reached the costal surface of the scapula, drawing‐in of the wires 3–4 cm when the subject adducted his arm, thereby rotating his scapula downward, and raw EMG recorded during typical movements. Additionally, in four shoulders, the electrode location was checked with computed tomography. There were no complications from this technique, and the subjects felt no pain from the fine‐wire electrodes during arm movements. We conclude that the described technique is a safe and reliable method of reaching the subscapularis muscle with EMG electrodes.Keywords
This publication has 10 references indexed in Scilit:
- Observations of the Function of the Shoulder JointClinical Orthopaedics and Related Research, 1996
- Fine wire electromyography analysis of muscles of the shoulder during swimmingThe American Journal of Sports Medicine, 1986
- An EMG analysis of the shoulder in throwing and pitchingThe American Journal of Sports Medicine, 1983
- Stabilizing mechanisms preventing anterior dislocation of the glenohumeral joint.Journal of Bone and Joint Surgery, 1981
- Recurrent anterior dislocation of the shoulder. Results after the Bankart and Putti-Platt operations.Journal of Bone and Joint Surgery, 1979
- Dynamic Stability of the Glenohumeral JointActa Orthopaedica, 1971
- A simple connector for fine-wire EMG electrodes.Journal of Applied Physiology, 1966
- A new bipolar electrode for electromyographyJournal of Applied Physiology, 1962