AN INVESTIGATION OF VARIABLES IN A FECAL FLOTATION TECHNIQUE

  • 1 January 1980
    • journal article
    • research article
    • Vol. 44  (2) , 148-154
Abstract
Several variables in a standard vial fecal gravitational flotation technique were investigated. These were the specific gravity of the sodium nitrate flotation solution, duration of flotation and mesh sizes of strainers. The number of eggs which floated and adhered to a coverslip were counted and estimates of the number of eggs remaining in the strained fecal suspension and in the feces trapped on the strainer were made. Eggs from hookworms, Trichuris vulpis and Toxocara canis in feces from dogs, Nematodirus spp. from sheep and Parascaris equorum from horses floated equally well in solutions with specific gravities (SpGr) ranging 1.22-1.38. Taenia spp. from dogs had a slightly narrower range (SpGr 1.27-1.38) for best recovery. Eggs from Haemonchus contortus from sheep appeared to float best between SpGr 1.22-1.32. Strongyles from 1 horse floated best with SpGr 1.27-1.32 and from another with SpGr 1.11-1.38. Coccidial oocysts from sheep floated best in a narrow range of SpGr from 1.22-1.27. As SpGr was increased the recognition of eggs under the coverslip was increasingly difficult and especially so at SpGr 1.38 with sheep feces. This was due to the increasing amount of debris and the more rapid formation of crystals with evaporation with solutions of higher SpGr. It appeared that solutions with SpGr of 1.22-1.35 would be best for routine laboratory use. At specific gravity 1.27, there appeared to be no difference in the number of eggs recovered for a 4-, 8- and 12-min flotation period. Only 3-7% of the eggs in 4 g of feces were counted under the coverslip. This poor efficacy resulted first because .apprx. 50% of the eggs were trapped in the feces and retained on the strainer. Only 1/2 of the strained fecal suspension, containing .apprx. 25% of the eggs, was placed in the vial for examination. Of those eggs in the vial only 16-29% were counted under the coverslip. When the 2nd half of the strained fecal suspension was placed in another vial, the amount of debris and air bubbles adhering to the coverslip was much less than that for the first vial. Egg counts for both vials appeared similar and it may be that when debris is excessive the fecal examination should involve counts from a second vial. The use of strainers finer than the standard tea strainer and the addition of minimal amounts of detergent did not increase the egg count.