Combination of Antitachycardia Pacemaker and Automatic Implantable Cardioverter/Defibrillator for Ventricular Tachycardia
- 1 September 1986
- journal article
- Published by Wiley in Pacing and Clinical Electrophysiology
- Vol. 9 (5) , 676-684
- https://doi.org/10.1111/j.1540-8159.1986.tb05415.x
Abstract
Antitachycardia pacing for ventricular tachycardia (VT) is associated with the possibility of fibrillating the heart; on the other hand, the frequency of VT and patient discomfort can limit treatment with the automatic implantable cardioverter/defibrillator (AICD). To contribute to the further development of a universal pacemaker, we evaluated the combined use of the antitachycardia pacemaker ("tachylog") and the AICD in five patients with recurrent VT. In the automatic mode, the "tachylog" worked as a bipolar VVI pacemaker. For antitachycardia pacing, a burst of rapid ventricular pacing was delivered at about 80% of the cycle length. During a follow-up period of 5 +/- 2 months (range, 3 to 8) two to 291 successful interventions of antitachycardia pacing were counted from diagnostic data which had been collected by the pulse generator during the course of treatment. When the antitachycardia pacemaker failed to terminate VT, the AICD was activated. In the individual case, between 0 and 41 discharges of the AICD were delivered. The high pulse energy of the AICD did not damage the antitachycardia pacemaker; no interference of the two devices was observed. Future antitachycardia systems should be more flexible with regard to detection and termination modes, combining antitachycardia pacing with back-up defibrillation.Keywords
This publication has 11 references indexed in Scilit:
- Erroneous discharge from an implanted automatic defibrillator during supraventricular tachyarrhythmia induced ventricular fibrillationThe American Journal of Cardiology, 1986
- Clinical experience, complications, and survival in 70 patients with the automatic implantable cardioverter/defibrillator.Circulation, 1985
- Clinical Results with the Tachylog Antitachycardia PacemakerPacing and Clinical Electrophysiology, 1984
- The automatic implantable defibrillator: Local ventricular bipolar sensing to detect ventricular tachycardia and fibrillationThe American Journal of Cardiology, 1983
- Mortality in Patients with Implanted Automatic DefibrillatorsAnnals of Internal Medicine, 1983
- Therapeutic Pacing in Tachyarrhythmias by Implanted PacemakersPacing and Clinical Electrophysiology, 1982
- Clinical treatment of life-threatening ventricular tachyarrhythmias with the automatic implantable defibrillatorAmerican Heart Journal, 1981
- PROGRAMMED STIMULATION FOR LONG-TERM TREATMENT AND NON-INVASIVE INVESTIGATION OF RECURRENT TACHYCARDIAThe Lancet, 1981
- Permanent Programmable Pacemakers in the Management of Recurrent Tachycardias*Pacing and Clinical Electrophysiology, 1979
- Termination of ventricular tachycardia with bursts of rapid ventricular pacingThe American Journal of Cardiology, 1978