Phosphorylcholine coating of extracorporeal circuits provides natural protection against blood activation by the material surface
Open Access
- 1 November 2000
- journal article
- clinical trial
- Published by Oxford University Press (OUP) in European Journal of Cardio-Thoracic Surgery
- Vol. 18 (5) , 602-606
- https://doi.org/10.1016/s1010-7940(00)00508-x
Abstract
Objective: The aim of this study is to evaluate the use of a new coating, mimicking the outer cell membrane, in paediatric cardiac surgery. Methods: Two groups of ten patients with a body weight below 8 kg, undergoing elective cardiac operations for different congenital anomalies, were prospectively enrolled in this study. In one group the whole extracorporeal circuit, including the cannulas, was coated with phosphorylcholine (PC). In the second group the same circuit was used without coating. Platelet activation (thromboxane B2 (TXB2), β-thromboglobulin (βTG)), activation of the coagulation system (F1+2), leukocyte activation (CD11b/CD18) and terminal complement activation (TCC) were analyzed pre-cardiopulmonary bypass (CPB), at 15, 60 min of CPB, at the end of CPB, 20 min post CPB and at postoperative day 1 and 6. Results: No statistical differences were found for F1+2 and CD11b/CD18. After onset of CPB mean levels of TCC remained stable in the PC group whereas an increase was observed in the control group. During CPB βTG values in both groups increased to a maximum at the end of CPB. Within groups the increase in βTG levels during CPB was statistically significant (P≪0.05) from baseline in the control group starting from 60 min of CPB whereas no statistical difference was observed in the PC group. After the start of CPB TXB2 mean levels increased to 405±249 pg/ml in the PC group vs. 535±224 pg/ml in the control group. After this initial increase there was a small decline in the PC group with further increase. This was in contrast to the control group were TXB2 levels further increased up to a mean of 718±333 pg/ml at the end of CPB (P=0.016). Conclusions: Phosphorylcholine coating had a favourable effect on blood platelets, which is most obvious after studying the changes during cardiopulmonary bypass. A steady increase of TXB2 and βTG was observed in the control group, whereas plateau formation was observed in the phosphorylcholine group. Clinically, this effect may contribute to reduced blood loss and less thromboembolic complications. Complement activation is lower in the coated group.Keywords
This publication has 9 references indexed in Scilit:
- Platelet adhesion onto wettability gradient surfaces in the absence and presence of plasma proteinsJournal of Biomedical Materials Research, 1998
- Heparin-coated bypass circuits: effects on inflammatory response in pediatric cardiac operationsThe Annals of Thoracic Surgery, 1998
- Release of Proinflammatory Cytokines During Pediatric Cardiopulmonary Bypass: Heparin-Bonded Versus Nonbonded OxygenatorsThe Annals of Thoracic Surgery, 1997
- Biocompatibility of Heparin‐Coated Circuits in Pediatric Cardiopulmonary BypassArtificial Organs, 1997
- Changes in Platelet, Granulocyte, and Complement Activation During Cardiopulmonary Bypass Using Heparin‐coated EquipmentArtificial Organs, 1996
- Hemocompatible Cellulose Dialysis Membranes Modified with Phospholipid PolymersArtificial Organs, 1995
- Adhesion and cytokine production by monocytes on poly(2‐methacryloyloxyethyl phosphorylcholine‐co‐alkyl methacrylate)‐coated polymersJournal of Biomedical Materials Research, 1995
- Phosphatidylcholine-coated chest tubes improve drainage after open heart operationThe Annals of Thoracic Surgery, 1993
- Does the conformation of adsorbed fibrinogen dictate platelet interactions with artificial surfaces?Blood, 1986