Association of ventilation system type with SBS symptoms in office workers
- 26 June 2002
- journal article
- review article
- Published by Hindawi Limited in Indoor Air
- Vol. 12 (2) , 98-112
- https://doi.org/10.1034/j.1600-0668.2002.01111.x
Abstract
This paper provides a synthesis of current knowledge about the associations of ventilation system types in office buildings with sick building syndrome (SBS) symptoms and discusses potential explanations for the associations. Most studies completed to date indicate that relative to natural ventilation, air conditioning, with or without humidification, was consistently associated with a statistically significant increase in the prevalence of one or more SBS symptoms, by approximately 30 to 200%. In two of three analyses from a single study (assessments), symptom prevalences were also significantly higher in air-conditioned buildings than in buildings with simple mechanical ventilation and no humidification. The available data also suggest, with less consistency, an increase in risk of symptoms with simple mechanical ventilation relative to natural ventilation. Insufficient information was available for conclusions about the potential increased risk of SBS symptoms with humidification or recirculation of return air. The statistically significant associations of mechanical ventilation and air conditioning with SBS symptoms are much more frequent than expected from chance and also not likely to be a consequence of confounding by several potential personal, job, or building-related confounders. Multiple deficiencies in HVAC system design, construction, operation, or maintenance, including some which cause pollutant emissions from HVAC systems, may contribute to the increases in symptom prevalences but other possible reasons remain unclear.Keywords
This publication has 27 references indexed in Scilit:
- Evaluation of Swedish ventilation systemsBuilding and Environment, 1998
- Impact of Temperature and Humidity on the Perception of Indoor Air QualityIndoor Air, 1998
- Evaluation of Fungal Growth on Fiberglass Duct Materials for Various Moisture, Soil, Use, and Temperature ConditionsIndoor Air, 1996
- HVAC Systems As Emission Sources Affecting Indoor Air Quality: A Critical ReviewHVAC&R Research, 1995
- Dust and the Sick Building SyndromeIndoor Air, 1994
- Phase 1 of the California Healthy Building Study: A SummaryIndoor Air, 1993
- Non-Specific Symptoms In Office Workers: A Review And Summary Of The Epidemiologic LiteratureIndoor Air, 1993
- Microbial Growth Control in Spray Humidifiers of Health FacilitiesIndoor Air, 1993
- Work-related illness in offices: A proposed model of the “sick building syndrome”Environment International, 1989
- The sick building syndrome: prevalence studies.BMJ, 1984