Activated clotting times and activated partial thromboplastin times in patients undergoing coronary angioplasty who receive bolus doses of heparin
- 1 August 1992
- journal article
- Published by Wiley in Catheterization and Cardiovascular Diagnosis
- Vol. 26 (4) , 260-263
- https://doi.org/10.1002/ccd.1810260404
Abstract
The accurate assessment of coagulation status is an important part of interventional procedures performed in the cardiac catheterization laboratory. While the traditional clinical means of assessing heparin anticoagulation has been with the activated partial thromboplastin time (APTT), the activated coagulation time (ACT) has come into widespread use in the catheterization laboratory as an assay of whole blood clotting time which can be performed rapidly at the bedside. The purpose of the present study was to (1) assess the anticoagulant effect of a 10,000 U bolus of heparin in PTCA patients and (2) document the relationship between ACTs and APTTs in a subset of these patients. Baseline and postheparin ACTs were measured using a HemoTec coagulation timer in 545 unselected PTCA patients. The average baseline ACT was 120 ± 22 sec. After a 10,000 U bolus of heparin the average ACT was 249 ± 44 sec; 58% of patients had an ACT < 250 sec, 17% had an ACT between 250 and 275 sec, 12% had an ACT between 275 and 300 sec, and 13% had an ACT >300 sec. A total of 175 paired ACT and APTT measurements were obtained in a random subset of these patients at baseline, after heparinization, and at 4–6 hr intervals after the procedure. The APTT was limited by absolute upper and lower limits of 150 and 22 sec; there were no such limits on the ACT. When limiting values were excluded, there was a strong overall correlation between ACT and APTT measurements (r = 0.92, p 0.001). We conclude that the activated coagulation time provides an accurate and reliable assessment of anticoagulation status. This test appears to be ideally suited for patients undergoing interventional procedures. There are, however, substantial differences in the automated systems currently in clinical use. The percent of patients achieving a target ACT of greater than 300 sec, as measured by a HemoTec system, after a 10,000 U bolus of heparin is low. These results are not extrapolatable to other ACT measurement techniques.Keywords
This publication has 14 references indexed in Scilit:
- Monitoring the effect of heparin by measurement of activated clotting time during and after percutaneous transluminal coronary angioplasty.Heart, 1990
- Adequate heparinization during PTCA: Assessment using activated clotting timesCatheterization and Cardiovascular Diagnosis, 1989
- The role of the activated clotting time in heparin administration and neutralization for cardiopulmonary bypassThe Journal of Thoracic and Cardiovascular Surgery, 1983
- Nonoperative Dilatation of Coronary-Artery StenosisNew England Journal of Medicine, 1979
- Adequate Anticoagulation During Cardiopulmonary Bypass Determined by Activated Clotting Time and the Appearance of Fibrin MonomerThe Annals of Thoracic Surgery, 1978
- Control of Heparinization by Activated Clotting Time During Bypass with Improved Postoperative HemostasisThe Annals of Thoracic Surgery, 1977
- Monitoring of intraoperative heparinization and blood loss following cardiopulmonary bypass surgeryThe Journal of Thoracic and Cardiovascular Surgery, 1977
- Use of the Activated Coagulation Time in Intraoperative Heparin Reversal for Cardiopulmonary OperationsThe Annals of Thoracic Surgery, 1975
- A Simple Method of Heparin Management During Prolonged Extracorporeal CirculationThe Annals of Thoracic Surgery, 1974
- Activated Coagulation Time of Whole BloodJAMA, 1966