A C OMPARISON OF B IPHASIC AND M ONOPHASIC S HOCKS FOR E XTERNAL D EFIBRILLATION
- 1 January 2000
- journal article
- clinical trial
- Published by Taylor & Francis in Prehospital Emergency Care
- Vol. 4 (4) , 305-313
- https://doi.org/10.1080/10903120090941001
Abstract
Background and Objective. The ability of a shock to defibrillate the heart depends on its waveform and energy. Past studies of biphasic truncated exponential (BTE) shocks for external defibrillation focused on low energy levels. This prospective, randomized, double-blind clinical trial compared the first-shock efficacies of 200-joule (J) BTE, 130-J BTE, and 200-J monophasic damped sine wave shocks. Methods. Ventricular fibrillation (VF) was induced in 115 patients during evaluation of implantable cardioverter-defibrillator function and 39 patients during electrophysiologic evaluation of ventricular arrhythmias. After 19 ± 10 seconds of VF, a randomized transthoracic shock was administered. Mean first-shock success rates of the three groups were compared using a “Tukey-like” statistical test, adjusting for multiple comparisons. Blood pressures and arterial oxygen saturations were measured before VF induction and 30, 90, and 150 seconds after successful defibrillation. Results. First-shock success rates were 61/68 (90%) for 200-J monophasic, 39/39 (100%) for 200-J biphasic, and 39/47 (83%) for 130-J biphasic shocks. The 200-J biphasic shocks were simultaneously superior in first-shock efficacy to both 200-J monophasic and 130-J biphasic shocks (experimentwise error rate, α < 0.01). There was no significant difference between the efficacies of 200-J monophasic and 130-J biphasic shocks, nor was there any significant difference between the three groups in hemodynamic parameters after successful shocks. Conclusions. Biphasic shocks of 200 J provide better first-shock defibrillation efficacy for short-duration VF than 200-J monophasic and 130-J biphasic shocks and thus may allow earlier termination of VF in cardiac arrest patients.Keywords
This publication has 12 references indexed in Scilit:
- Evaluation of Biphasic Transthoracic Defibrillation in an Animal Model of Prolonged Ventricular FibrillationAcademic Emergency Medicine, 1999
- Microbubbles Targeted to Intercellular Adhesion Molecule-1 Bind to Activated Coronary Artery Endothelial CellsCirculation, 1998
- Use of cardiac troponin t rapid assay in the diagnosis of a myocardial injury secondary to electrical cardioversionClinical Cardiology, 1997
- Automatic External Defibrillators for Public Access Defibrillation: Recommendations for Specifying and Reporting Arrhythmia Analysis Algorithm Performance, Incorporating New Waveforms, and Enhancing SafetyCirculation, 1997
- Multicenter Comparison of Truncated Biphasic Shocks and Standard Damped Sine Wave Monophasic Shocks for Transthoracic Ventricular DefibrillationCirculation, 1996
- High Discharge Survival Rate After Out-of-Hospital Ventricular Fibrillation With Rapid Defibrillation by Police and ParamedicsAnnals of Emergency Medicine, 1996
- Choosing the Optimal Monophasic and Biphasic Waveforms for Ventricular DefibrillationJournal of Cardiovascular Electrophysiology, 1995
- Effect of paddle placement and size on defibrillation current distribution: a three-dimensional finite element modelIEEE Transactions on Biomedical Engineering, 1993
- Electrode pad size, transthoracic impedance and success of external ventricular defibrillationThe American Journal of Cardiology, 1989
- Improved low energy defibrillation efficacy in man with the use of a biphasic truncated exponential waveformAmerican Heart Journal, 1989