Image quantification with a large area multiwire proportional chamber positron camera (MUP-PET)
- 1 January 1989
- journal article
- research article
- Published by Springer Nature in European Journal of Nuclear Medicine and Molecular Imaging
- Vol. 15 (11) , 694-700
- https://doi.org/10.1007/bf00631759
Abstract
A large area multi wire proportional chamber positron camera system is under evaluation for clinical Nuclear Medicine investigation using isotopes both from in house generators (68Ga) and from remote cyclotrons (18F,124I,64Cu and81Rb). Images are reconstructed using a fully three dimensional (3D) algorithm and exhibit equal resolution in all three orthogonal directions. The axial field of view of 15 cm is large enough to allow coverage of the whole brain. This paper discusses the performance of the MUP-PET system with particular emphasis on quantification and the development of an attenuation correction scheme for a large area detector system. The distribution of scattered and accidental events is investigated and observed to contribute a fairly uniform background to the image. Dead time correction factors are calculated from an analytical expression obtained by considering the various sources of dead time present in the system. Following correction for atternuation, accidentals, scattered events and dead time, reconstructed phantom images show a strong linear correlation (r=0.998) between count density and regional isotope concentration. The extension of the methods to clinical studies is discussed.Keywords
This publication has 22 references indexed in Scilit:
- Photon mass attenuation and energy-absorption coefficientsPublished by Elsevier ,2002
- Three dimensional reconstruction of PET data from a multi-ring cameraIEEE Transactions on Nuclear Science, 1989
- Investigation of Count Rate and Deadtime Characteristics of a High Resolution PET SystemJournal of Computer Assisted Tomography, 1988
- Compton scattering in a large-aperture positron imaging systemIEEE Transactions on Medical Imaging, 1988
- The development of high-efficiency cathode converters for a multiwire proportional chamber positron cameraMedical Physics, 1986
- Scatter Distribution in Transmission Measurements with Positron Emission TomographyJournal of Computer Assisted Tomography, 1986
- Increased sensitivity and field of view for a rotating positron cameraPhysics in Medicine & Biology, 1984
- Correction for Scattered Radiation in a Ring Detector Positron Camera by Integral Transformation of the ProjectionsJournal of Computer Assisted Tomography, 1983
- Quantitation in Positron Emission Computed TomographyJournal of Computer Assisted Tomography, 1981
- Quantitation in Positron Emission Computed TomographyJournal of Computer Assisted Tomography, 1979